PT CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

PhaseGreen Technology PhG-P6K0LNA-M (6.117 kW)

6 kW, 240 Vac Grid Support Hybrid Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6.117 kW
CEC Weighted Eff.
97%
MPPT / Max DC
200–430V / 430V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
PhaseGreen Technology PhG-P6K0LNA-M — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–430 Vdc 200V 430V MAX 430V PV DC INPUT ≤ 430V DC 6.117 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

PhaseGreen Technology PhG-P6K0LNA-M Electrical and Grid-Support Specifications
ManufacturerPhaseGreen Technology
Model Number (MPN)PhG-P6K0LNA-M
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)6.117 kW (6,117 W)
Nominal DC Input (Pdco)6,298 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window200 – 430 Vdc (NREL SAM Measured)
Max DC Input Voltage430 Vdc
Max DC Input Current17.5 A
Night Tare Loss22.99 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for PhG-P6K0LNA-M
Max Continuous AC Current25.5 A @ 240V
125% Continuous Duty Current31.9 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.73–8.26 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for PhG-P6K0LNA-M
Panel ClassRecommended QtyDC Array / Ratio
400W17–21 panels6.8–8.4 kW DC
440W15–19 panels6.6–8.4 kW DC
550W12–15 panels6.6–8.3 kW DC

Compatible Solar Panels for PhaseGreen Technology PhG-P6K0LNA-M

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for PhaseGreen Technology PhG-P6K0LNA-M
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — PhaseGreen Technology PhG-P6K0LNA-M

What size circuit breaker does the PhaseGreen Technology PhG-P6K0LNA-M require under NEC 705.12?
At 6.117 kW continuous AC output on 240V (25.5A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the PhaseGreen Technology PhG-P6K0LNA-M?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.117 kW unit with 6.73 kW to 8.26 kW DC of solar modules without exceeding 430V cold Voc.

More PhaseGreen Technology Inverters

PhG-P8K0LNA-M (8.084 kW)PhG-P10K0LNA-M (10.177 kW)PhG-P5K0LNA-M (5.09 kW)PhG-P7K6LNA-M (7.765 kW)All PhaseGreen Technology Equipment →