PE CEC-Listed · 240V ResidentialString

Pika Energy X7603 (7.585 kW)

7.6 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.585 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
390–420V / 420V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Pika Energy X7603 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 390–420 Vdc 390V 420V MAX 420V PV DC INPUT ≤ 420V DC 7.585 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Pika Energy X7603 Electrical and Grid-Support Specifications
ManufacturerPika Energy
Model Number (MPN)X7603
Inverter TopologyString Inverter
Continuous AC Power (Paco)7.585 kW (7,585 W)
Nominal DC Input (Pdco)7,823 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window390 – 420 Vdc (NREL SAM Measured)
Max DC Input Voltage420 Vdc
Max DC Input Current19.6 A
Night Tare Loss1.29 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for X7603
Max Continuous AC Current31.6 A @ 240V
125% Continuous Duty Current39.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.34–10.24 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for X7603
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Engineering FAQ — Pika Energy X7603

What size circuit breaker does the Pika Energy X7603 require under NEC 705.12?
At 7.585 kW continuous AC output on 240V (31.6A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Pika Energy X7603?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.585 kW unit with 8.34 kW to 10.24 kW DC of solar modules without exceeding 420V cold Voc.

More Pika Energy Inverters

X7601 (7.587 kW)X7602 (7.587 kW)All Pika Energy Equipment →