PE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

PointGuard Energy PG Controller 3.8 (3.843 kW)

3.8 kW, 240 Vac Grid Support Utility Interactive Hybrid Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.843 kW
CEC Weighted Eff.
97%
MPPT / Max DC
270–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
PointGuard Energy PG Controller 3.8 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 270–480 Vdc 270V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.843 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

PointGuard Energy PG Controller 3.8 Electrical and Grid-Support Specifications
ManufacturerPointGuard Energy
Model Number (MPN)PG Controller 3.8
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.843 kW (3,843 W)
Nominal DC Input (Pdco)3,952 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window270 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current11 A
Night Tare Loss3.26 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for PG Controller 3.8
Max Continuous AC Current16 A @ 240V
125% Continuous Duty Current20.0 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.23–5.19 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for PG Controller 3.8
Panel ClassRecommended QtyDC Array / Ratio
400W11–13 panels4.4–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–9 panels4.4–5.0 kW DC

Compatible Solar Panels for PointGuard Energy PG Controller 3.8

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for PointGuard Energy PG Controller 3.8
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — PointGuard Energy PG Controller 3.8

What size circuit breaker does the PointGuard Energy PG Controller 3.8 require under NEC 705.12?
At 3.843 kW continuous AC output on 240V (16A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the PointGuard Energy PG Controller 3.8?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.843 kW unit with 4.23 kW to 5.19 kW DC of solar modules without exceeding 480V cold Voc.

More PointGuard Energy Inverters

PG Controller 7.6 (7.689 kW)PG Controller 9.6 (9.653 kW)PG Controller 11.4 (11.46 kW)PG Controller 4.8 (4.808 kW)PG Controller 5.7 (5.776 kW)All PointGuard Energy Equipment →