PO CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

POMCube PNZ-10K1N2-NA0 (9.92 kW)

10 kW, 240 Vac Split Phase, Transformerless Grid Support Utility Interactive Hybrid Inverter for PV and Energy Storage Application. The inverter is capable of PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.92 kW
CEC Weighted Eff.
94%
MPPT / Max DC
250–530V / 530V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
POMCube PNZ-10K1N2-NA0 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–530 Vdc 250V 530V MAX 530V PV DC INPUT ≤ 530V DC 9.92 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

POMCube PNZ-10K1N2-NA0 Electrical and Grid-Support Specifications
ManufacturerPOMCube
Model Number (MPN)PNZ-10K1N2-NA0
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.92 kW (9,920 W)
Nominal DC Input (Pdco)10,509 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency94%
MPPT Operating Window250 – 530 Vdc (NREL SAM Measured)
Max DC Input Voltage530 Vdc
Max DC Input Current29.2 A
Night Tare Loss21.92 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for PNZ-10K1N2-NA0
Max Continuous AC Current41.3 A @ 240V
125% Continuous Duty Current51.6 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.91–13.39 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for PNZ-10K1N2-NA0
Panel ClassRecommended QtyDC Array / Ratio
400W27–33 panels10.8–13.2 kW DC
440W25–30 panels11.0–13.2 kW DC
550W20–24 panels11.0–13.2 kW DC

Compatible Solar Panels for POMCube PNZ-10K1N2-NA0

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for POMCube PNZ-10K1N2-NA0
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–9 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–7 per string (-10°C)Verify Pair

Engineering FAQ — POMCube PNZ-10K1N2-NA0

What size circuit breaker does the POMCube PNZ-10K1N2-NA0 require under NEC 705.12?
At 9.92 kW continuous AC output on 240V (41.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the POMCube PNZ-10K1N2-NA0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.92 kW unit with 10.91 kW to 13.39 kW DC of solar modules without exceeding 530V cold Voc.