Qcells (Hanwha) Q.HOME+ HYB-G1-7.0 (6.666 kW)
7.0 kW, 240 Vac, single-phase, hybrid PV and battery, grid support utility interactive inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
6.666 kW
CEC Weighted Eff.
94.5%
MPPT / Max DC
290–425V / 425V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Qcells (Hanwha) |
|---|---|
| Model Number (MPN) | Q.HOME+ HYB-G1-7.0 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 6.666 kW (6,666 W) |
| Nominal DC Input (Pdco) | 7,018 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 94.5% |
| MPPT Operating Window | 290 – 425 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 425 Vdc |
| Max DC Input Current | 19.5 A |
| Night Tare Loss | 25 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 27.8 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 34.8 A |
| Minimum Standard Breaker | 35 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (7.33–9 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 18–23 panels | 7.2–9.2 kW DC |
| 440W | 17–20 panels | 7.5–8.8 kW DC |
| 550W | 13–16 panels | 7.2–8.8 kW DC |
Compatible Solar Panels for Qcells (Hanwha) Q.HOME+ HYB-G1-7.0
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 11–11 per string (-10°C) | Verify Pair |
| REC Solar REC430AA Pure 2 | 430 W | 49 V | 8–8 per string (-10°C) | Verify Pair |
Engineering FAQ — Qcells (Hanwha) Q.HOME+ HYB-G1-7.0
What size circuit breaker does the Qcells (Hanwha) Q.HOME+ HYB-G1-7.0 require under NEC 705.12?
At 6.666 kW continuous AC output on 240V (27.8A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Qcells (Hanwha) Q.HOME+ HYB-G1-7.0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.666 kW unit with 7.33 kW to 9 kW DC of solar modules without exceeding 425V cold Voc.