Qcells (Hanwha) official logoCEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Qcells (Hanwha) Q.MICRO.380C-G2# (0.379 kW)

380 W, 240 Vac Grid Support Utility Interactive Microinverter for ACPV Module applications. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.379 kW
CEC Weighted Eff.
97%
MPPT / Max DC
30–40V / 40V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Qcells (Hanwha) Q.MICRO.380C-G2# — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 30–40 Vdc 30V 40V MAX 40V PV DC INPUT ≤ 40V DC 0.379 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Qcells (Hanwha) Q.MICRO.380C-G2# Electrical and Grid-Support Specifications
ManufacturerQcells (Hanwha)
Model Number (MPN)Q.MICRO.380C-G2#
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.379 kW (379 W)
Nominal DC Input (Pdco)390 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window30 – 40 Vdc (NREL SAM Measured)
Max DC Input Voltage40 Vdc
Max DC Input Current12 A
Night Tare Loss0.03 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryUL
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Q.MICRO.380C-G2#
Max Continuous AC Current1.6 A @ 240V
125% Continuous Duty Current2.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.42–0.51 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Q.MICRO.380C-G2#
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.06× DC/AC)
440W1 panel1:1 pairing (1.16× DC/AC)
550W1 panel1:1 pairing (1.45× DC/AC)

Compatible Solar Panels for Qcells (Hanwha) Q.MICRO.380C-G2#

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Qcells (Hanwha) Q.MICRO.380C-G2#
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.53 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.53 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.52 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.48 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.46 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 1.25 (1 panel/input)Verify Pair

Engineering FAQ — Qcells (Hanwha) Q.MICRO.380C-G2#

What size circuit breaker does the Qcells (Hanwha) Q.MICRO.380C-G2# require under NEC 705.12?
At 0.379 kW continuous AC output on 240V (1.6A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Qcells (Hanwha) Q.MICRO.380C-G2#?
As a 379W microinverter, it pairs 1:1 with panels rated roughly 398W to 550W STC.

More Qcells (Hanwha) Inverters

Q.MI.349B-G1 (0.349 kW)Q.TRON BLK M-G2.D1+/AC 415 (0.349 kW)Q.MI.380C-G2 (0.379 kW)Q.MI.384B-P2 (0.383 kW)Q.VOLT H3.8SX (3.805 kW)Q.VOLT A3.8SX (3.81 kW)All Qcells (Hanwha) Equipment →