RCT Power Energy Technology Power Storage DC US-15.0 (14.947 kW)
15 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
14.947 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
220–440V / 440V
NEC 705.12 Breaker
80A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | RCT Power Energy Technology |
|---|---|
| Model Number (MPN) | Power Storage DC US-15.0 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 14.947 kW (14,947 W) |
| Nominal DC Input (Pdco) | 15,635 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 95.5% |
| MPPT Operating Window | 220 – 440 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 440 Vdc |
| Max DC Input Current | 41.1 A |
| Night Tare Loss | 16.1 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 62.3 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 77.9 A |
| Minimum Standard Breaker | 80 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (16.44–20.18 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 41–50 panels | 16.4–20.0 kW DC |
| 440W | 37–46 panels | 16.3–20.2 kW DC |
| 550W | 30–37 panels | 16.5–20.4 kW DC |
Compatible Solar Panels for RCT Power Energy Technology Power Storage DC US-15.0
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 6–7 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 6–7 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 6–7 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–8 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 5–6 per string (-10°C) | Verify Pair |
Engineering FAQ — RCT Power Energy Technology Power Storage DC US-15.0
What size circuit breaker does the RCT Power Energy Technology Power Storage DC US-15.0 require under NEC 705.12?
At 14.947 kW continuous AC output on 240V (62.3A continuous), the 125% continuous duty rule requires a minimum 80A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the RCT Power Energy Technology Power Storage DC US-15.0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 14.947 kW unit with 16.44 kW to 20.18 kW DC of solar modules without exceeding 440V cold Voc.