RP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

RCT Power Energy Technology Power Storage DC US-15.0 (14.947 kW)

15 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
14.947 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
220–440V / 440V
NEC 705.12 Breaker
80A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
RCT Power Energy Technology Power Storage DC US-15.0 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 220–440 Vdc 220V 440V MAX 440V PV DC INPUT ≤ 440V DC 14.947 kW · 95.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 80A BRKR

Electrical & Grid-Support Datasheet

RCT Power Energy Technology Power Storage DC US-15.0 Electrical and Grid-Support Specifications
ManufacturerRCT Power Energy Technology
Model Number (MPN)Power Storage DC US-15.0
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)14.947 kW (14,947 W)
Nominal DC Input (Pdco)15,635 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency95.5%
MPPT Operating Window220 – 440 Vdc (NREL SAM Measured)
Max DC Input Voltage440 Vdc
Max DC Input Current41.1 A
Night Tare Loss16.1 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Power Storage DC US-15.0
Max Continuous AC Current62.3 A @ 240V
125% Continuous Duty Current77.9 A
Minimum Standard Breaker80 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (16.44–20.18 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Power Storage DC US-15.0
Panel ClassRecommended QtyDC Array / Ratio
400W41–50 panels16.4–20.0 kW DC
440W37–46 panels16.3–20.2 kW DC
550W30–37 panels16.5–20.4 kW DC

Compatible Solar Panels for RCT Power Energy Technology Power Storage DC US-15.0

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for RCT Power Energy Technology Power Storage DC US-15.0
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — RCT Power Energy Technology Power Storage DC US-15.0

What size circuit breaker does the RCT Power Energy Technology Power Storage DC US-15.0 require under NEC 705.12?
At 14.947 kW continuous AC output on 240V (62.3A continuous), the 125% continuous duty rule requires a minimum 80A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the RCT Power Energy Technology Power Storage DC US-15.0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 14.947 kW unit with 16.44 kW to 20.18 kW DC of solar modules without exceeding 440V cold Voc.

More RCT Power Energy Technology Inverters