RE CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

RelyEZ Energy Storage Technology Sync Micro 760S (0.76 kW)

0.76 kW, 240Vac Grid Support Utility Interactive PV Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.76 kW
CEC Weighted Eff.
95%
MPPT / Max DC
50–76V / 76V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
RelyEZ Energy Storage Technology Sync Micro 760S — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 50–76 Vdc 50V 76V MAX 76V PV DC INPUT ≤ 76V DC 0.76 kW · 95% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

RelyEZ Energy Storage Technology Sync Micro 760S Electrical and Grid-Support Specifications
ManufacturerRelyEZ Energy Storage Technology
Model Number (MPN)Sync Micro 760S
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.76 kW (760 W)
Nominal DC Input (Pdco)790 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency95%
MPPT Operating Window50 – 76 Vdc (NREL SAM Measured)
Max DC Input Voltage76 Vdc
Max DC Input Current12.5 A
Night Tare Loss0.04 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Sync Micro 760S
Max Continuous AC Current3.2 A @ 240V
125% Continuous Duty Current4.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.84–1.03 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Sync Micro 760S
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.53× DC/AC)
440W1 panel1:1 pairing (0.58× DC/AC)
550W1 panel1:1 pairing (0.72× DC/AC)

Engineering FAQ — RelyEZ Energy Storage Technology Sync Micro 760S

What size circuit breaker does the RelyEZ Energy Storage Technology Sync Micro 760S require under NEC 705.12?
At 0.76 kW continuous AC output on 240V (3.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the RelyEZ Energy Storage Technology Sync Micro 760S?
As a 760W microinverter, it pairs 1:1 with panels rated roughly 798W to 1102W STC.

More RelyEZ Energy Storage Technology Inverters

Sync Micro 550S (0.55 kW)Sync Micro 660S (0.66 kW)All RelyEZ Energy Storage Technology Equipment →