RI CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

RNG International RIV4880HI-SPS (8.084 kW)

8 kW, 240 Vac Grid Support Hybrid Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.084 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
250–430V / 430V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
RNG International RIV4880HI-SPS — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–430 Vdc 250V 430V MAX 430V PV DC INPUT ≤ 430V DC 8.084 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

RNG International RIV4880HI-SPS Electrical and Grid-Support Specifications
ManufacturerRNG International
Model Number (MPN)RIV4880HI-SPS
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)8.084 kW (8,084 W)
Nominal DC Input (Pdco)8,327 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window250 – 430 Vdc (NREL SAM Measured)
Max DC Input Voltage430 Vdc
Max DC Input Current23.1 A
Night Tare Loss17.4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for RIV4880HI-SPS
Max Continuous AC Current33.7 A @ 240V
125% Continuous Duty Current42.1 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.89–10.91 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for RIV4880HI-SPS
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–25 panels8.8–11.0 kW DC
550W16–20 panels8.8–11.0 kW DC

Compatible Solar Panels for RNG International RIV4880HI-SPS

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for RNG International RIV4880HI-SPS
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — RNG International RIV4880HI-SPS

What size circuit breaker does the RNG International RIV4880HI-SPS require under NEC 705.12?
At 8.084 kW continuous AC output on 240V (33.7A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the RNG International RIV4880HI-SPS?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.084 kW unit with 8.89 kW to 10.91 kW DC of solar modules without exceeding 430V cold Voc.

More RNG International Inverters

RIV4850HI-SPS (5.09 kW)RIV4860HI-SPS (6.117 kW)RIV4876HI-SPS (7.765 kW)RIV4810HI-SPS (10.177 kW)All RNG International Equipment →