Savant Power PS-INV-10KW-60A-XX (9.923 kW)
10 kW, 240 Vac Transformerless Grid Support Utility Interactive Hybrid Inverter, where XX can be any letters, numbers, or symbols. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
9.923 kW
CEC Weighted Eff.
94%
MPPT / Max DC
250–530V / 530V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Savant Power |
|---|---|
| Model Number (MPN) | PS-INV-10KW-60A-XX |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 9.923 kW (9,923 W) |
| Nominal DC Input (Pdco) | 10,512 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 94% |
| MPPT Operating Window | 250 – 530 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 530 Vdc |
| Max DC Input Current | 29.2 A |
| Night Tare Loss | 21.92 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 41.3 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 51.6 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (10.92–13.4 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 27–34 panels | 10.8–13.6 kW DC |
| 440W | 25–30 panels | 11.0–13.2 kW DC |
| 550W | 20–24 panels | 11.0–13.2 kW DC |
Compatible Solar Panels for Savant Power PS-INV-10KW-60A-XX
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 7–9 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 7–9 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 7–9 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–9 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–9 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–7 per string (-10°C) | Verify Pair |
Engineering FAQ — Savant Power PS-INV-10KW-60A-XX
What size circuit breaker does the Savant Power PS-INV-10KW-60A-XX require under NEC 705.12?
At 9.923 kW continuous AC output on 240V (41.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Savant Power PS-INV-10KW-60A-XX?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.923 kW unit with 10.92 kW to 13.4 kW DC of solar modules without exceeding 530V cold Voc.