Schneider Electric official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Schneider Electric XW Pro 6848 NA (6.019 kW)

6 kW, 240 Vac, Special Purpose Grid Support Utility Interactive Battery Inverter/Charger/Stand-alone, with PCS Functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6.019 kW
CEC Weighted Eff.
94%
MPPT / Max DC
120–500V / 600V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Schneider Electric XW Pro 6848 NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 6.019 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Schneider Electric XW Pro 6848 NA Electrical and Grid-Support Specifications
ManufacturerSchneider Electric
Model Number (MPN)XW Pro 6848 NA
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)6.019 kW (6,019 W)
Nominal DC Input (Pdco)6,528 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants120V, 240V
CEC Weighted Efficiency94%
MPPT Operating Window120 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current125.5 A
Night Tare Loss0.37 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for XW Pro 6848 NA
Max Continuous AC Current25.1 A @ 240V
125% Continuous Duty Current31.4 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.62–8.13 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for XW Pro 6848 NA
Panel ClassRecommended QtyDC Array / Ratio
400W17–20 panels6.8–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–15 panels6.6–8.3 kW DC

Compatible Solar Panels for Schneider Electric XW Pro 6848 NA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Schneider Electric XW Pro 6848 NA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — Schneider Electric XW Pro 6848 NA

What size circuit breaker does the Schneider Electric XW Pro 6848 NA require under NEC 705.12?
At 6.019 kW continuous AC output on 240V (25.1A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Schneider Electric XW Pro 6848 NA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.019 kW unit with 6.62 kW to 8.13 kW DC of solar modules without exceeding 600V cold Voc.

More Schneider Electric Inverters

HY8K1NA1 (7.626 kW)All Schneider Electric Equipment →