SG CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Shenzhen GSL Energy HS-LV10KNA (10.008 kW)

10 kW, 240 Vac Grid Support Utility Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
10.008 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
275–450V / 450V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Shenzhen GSL Energy HS-LV10KNA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 275–450 Vdc 275V 450V MAX 450V PV DC INPUT ≤ 450V DC 10.008 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Shenzhen GSL Energy HS-LV10KNA Electrical and Grid-Support Specifications
ManufacturerShenzhen GSL Energy
Model Number (MPN)HS-LV10KNA
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)10.008 kW (10,008 W)
Nominal DC Input (Pdco)10,509 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window275 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current29 A
Night Tare Loss73.6 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HS-LV10KNA
Max Continuous AC Current41.7 A @ 240V
125% Continuous Duty Current52.1 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (11.01–13.51 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HS-LV10KNA
Panel ClassRecommended QtyDC Array / Ratio
400W28–34 panels11.2–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Compatible Solar Panels for Shenzhen GSL Energy HS-LV10KNA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Shenzhen GSL Energy HS-LV10KNA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V11–11 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445445 W40.16 V10–10 per string (-10°C)Verify Pair

Engineering FAQ — Shenzhen GSL Energy HS-LV10KNA

What size circuit breaker does the Shenzhen GSL Energy HS-LV10KNA require under NEC 705.12?
At 10.008 kW continuous AC output on 240V (41.7A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Shenzhen GSL Energy HS-LV10KNA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10.008 kW unit with 11.01 kW to 13.51 kW DC of solar modules without exceeding 450V cold Voc.

More Shenzhen GSL Energy Inverters

GSL-H-12KLV-US (11.933 kW)HS-LV12KNA (11.996 kW)HS-LV8KNA (8.81 kW)All Shenzhen GSL Energy Equipment →