Shenzhen Poweroak Newener EnergyPro 6K (5.777 kW)
5.777 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
5.777 kW
CEC Weighted Eff.
95%
MPPT / Max DC
63–500V / 600V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Shenzhen Poweroak Newener |
|---|---|
| Model Number (MPN) | EnergyPro 6K |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 5.777 kW (5,777 W) |
| Nominal DC Input (Pdco) | 6,067 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 95% |
| MPPT Operating Window | 63 – 500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 600 Vdc |
| Max DC Input Current | 79.8 A |
| Night Tare Loss | 10.68 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 24.1 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 30.1 A |
| Minimum Standard Breaker | 35 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (6.35–7.8 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 16–20 panels | 6.4–8.0 kW DC |
| 440W | 14–18 panels | 6.2–7.9 kW DC |
| 550W | 12–14 panels | 6.6–7.7 kW DC |
Compatible Solar Panels for Shenzhen Poweroak Newener EnergyPro 6K
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 2–10 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 2–10 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 2–10 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 2–10 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 2–11 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 2–8 per string (-10°C) | Verify Pair |
Engineering FAQ — Shenzhen Poweroak Newener EnergyPro 6K
What size circuit breaker does the Shenzhen Poweroak Newener EnergyPro 6K require under NEC 705.12?
At 5.777 kW continuous AC output on 240V (24.1A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Shenzhen Poweroak Newener EnergyPro 6K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.777 kW unit with 6.35 kW to 7.8 kW DC of solar modules without exceeding 600V cold Voc.