SP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Shenzhen Poweroak Newener EnergyPro 6K (5.777 kW)

5.777 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.777 kW
CEC Weighted Eff.
95%
MPPT / Max DC
63–500V / 600V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Shenzhen Poweroak Newener EnergyPro 6K — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 63–500 Vdc 63V 500V MAX 600V PV DC INPUT ≤ 600V DC 5.777 kW · 95% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Shenzhen Poweroak Newener EnergyPro 6K Electrical and Grid-Support Specifications
ManufacturerShenzhen Poweroak Newener
Model Number (MPN)EnergyPro 6K
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.777 kW (5,777 W)
Nominal DC Input (Pdco)6,067 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency95%
MPPT Operating Window63 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current79.8 A
Night Tare Loss10.68 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for EnergyPro 6K
Max Continuous AC Current24.1 A @ 240V
125% Continuous Duty Current30.1 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.35–7.8 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for EnergyPro 6K
Panel ClassRecommended QtyDC Array / Ratio
400W16–20 panels6.4–8.0 kW DC
440W14–18 panels6.2–7.9 kW DC
550W12–14 panels6.6–7.7 kW DC

Compatible Solar Panels for Shenzhen Poweroak Newener EnergyPro 6K

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Shenzhen Poweroak Newener EnergyPro 6K
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V2–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V2–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V2–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V2–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V2–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V2–8 per string (-10°C)Verify Pair

Engineering FAQ — Shenzhen Poweroak Newener EnergyPro 6K

What size circuit breaker does the Shenzhen Poweroak Newener EnergyPro 6K require under NEC 705.12?
At 5.777 kW continuous AC output on 240V (24.1A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Shenzhen Poweroak Newener EnergyPro 6K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.777 kW unit with 6.35 kW to 7.8 kW DC of solar modules without exceeding 600V cold Voc.

More Shenzhen Poweroak Newener Inverters

EP900 (9.23 kW)EnergyPro 13K (13.196 kW)All Shenzhen Poweroak Newener Equipment →