SS CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Shenzhen Senergy Technology SE 5KHB-130-D2/UL (5.04 kW)

5 kW, 240 Vac, Grid Support Utility Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.04 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–480V / 480V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Shenzhen Senergy Technology SE 5KHB-130-D2/UL — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–480 Vdc 200V 480V MAX 480V PV DC INPUT ≤ 480V DC 5.04 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

Shenzhen Senergy Technology SE 5KHB-130-D2/UL Electrical and Grid-Support Specifications
ManufacturerShenzhen Senergy Technology
Model Number (MPN)SE 5KHB-130-D2/UL
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.04 kW (5,040 W)
Nominal DC Input (Pdco)5,196 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window200 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current14.4 A
Night Tare Loss15 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE 5KHB-130-D2/UL
Max Continuous AC Current21 A @ 240V
125% Continuous Duty Current26.3 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.54–6.8 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE 5KHB-130-D2/UL
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W13–15 panels5.7–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for Shenzhen Senergy Technology SE 5KHB-130-D2/UL

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Shenzhen Senergy Technology SE 5KHB-130-D2/UL
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Shenzhen Senergy Technology SE 5KHB-130-D2/UL

What size circuit breaker does the Shenzhen Senergy Technology SE 5KHB-130-D2/UL require under NEC 705.12?
At 5.04 kW continuous AC output on 240V (21A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Shenzhen Senergy Technology SE 5KHB-130-D2/UL?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.04 kW unit with 5.54 kW to 6.8 kW DC of solar modules without exceeding 480V cold Voc.

More Shenzhen Senergy Technology Inverters

SE 11K4HB-210-T2/UL (10.14 kW)SE 10KHB-210-T2/UL (10.147 kW)SE 11K4HB-T2/LV-ULP (11.567 kW)SE 6KHB-130-D2/UL (6.149 kW)SE 7K6HB-180-T2/UL (7.647 kW)SE 8KHB-180-T2/UL (8.047 kW)All Shenzhen Senergy Technology Equipment →