SMA Solar official logoCEC-Listed · 240V ResidentialHybridBattery Hybrid

SMA Solar SBS3.8-US-10 (3.8 kW)

3.8 kW, 240 Vac, 1-phase, Sunny Boy Storage- Permanently-connected, Transformerless Multimode - Grid Support Utility Interactive and Standalone functionality - Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.8 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
220–550V / 550V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SMA Solar SBS3.8-US-10 — Real SMA Sunny Boy solar inverter
Real SMA Sunny Boy solar inverterWikimedia Commons — File:Dornbirn-SMA Sunny Boy inverter SWR 3000-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 220–550 Vdc 220V 550V MAX 550V PV DC INPUT ≤ 550V DC 3.8 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

SMA Solar SBS3.8-US-10 Electrical and Grid-Support Specifications
ManufacturerSMA Solar
Model Number (MPN)SBS3.8-US-10
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.8 kW (3,800 W)
Nominal DC Input (Pdco)3,924 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window220 – 550 Vdc (NREL SAM Measured)
Max DC Input Voltage550 Vdc
Max DC Input Current10.9 A
Night Tare Loss6.53 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SBS3.8-US-10
Max Continuous AC Current15.8 A @ 240V
125% Continuous Duty Current19.8 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.18–5.13 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SBS3.8-US-10
Panel ClassRecommended QtyDC Array / Ratio
400W10–13 panels4.0–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–9 panels4.4–5.0 kW DC

Compatible Solar Panels for SMA Solar SBS3.8-US-10

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SMA Solar SBS3.8-US-10
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–9 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–10 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–7 per string (-10°C)Verify Pair

Engineering FAQ — SMA Solar SBS3.8-US-10

What size circuit breaker does the SMA Solar SBS3.8-US-10 require under NEC 705.12?
At 3.8 kW continuous AC output on 240V (15.8A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SMA Solar SBS3.8-US-10?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.8 kW unit with 4.18 kW to 5.13 kW DC of solar modules without exceeding 550V cold Voc.

More SMA Solar Inverters

SBSE11.5-US-50 (11.483 kW)SB3.0-1SP-US-40 (3 kW)SB3.8-1SP-US-40 (3.8 kW)SB3.8-1SP-US-41 (3.84 kW)SBSE3.8-US-50 (3.87 kW)SBSE4.8-US-50 (4.823 kW)All SMA Solar Equipment →