SX CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

SolaX Power A1-AC-3.8K-G2 (3.81 kW)

3.8 kW, 240 Vac Grid support utility-interactive Power Conversion System, with Backup Interface (BI), A1-BI-200-G2. Capable of PCS funcitonality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.81 kW
CEC Weighted Eff.
95%
MPPT / Max DC
76–450V / 450V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolaX Power A1-AC-3.8K-G2 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 76–450 Vdc 76V 450V MAX 450V PV DC INPUT ≤ 450V DC 3.81 kW · 95% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

SolaX Power A1-AC-3.8K-G2 Electrical and Grid-Support Specifications
ManufacturerSolaX Power
Model Number (MPN)A1-AC-3.8K-G2
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.81 kW (3,810 W)
Nominal DC Input (Pdco)3,981 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency95%
MPPT Operating Window76 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current15.1 A
Night Tare Loss1.2 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for A1-AC-3.8K-G2
Max Continuous AC Current15.9 A @ 240V
125% Continuous Duty Current19.9 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.19–5.14 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for A1-AC-3.8K-G2
Panel ClassRecommended QtyDC Array / Ratio
400W10–13 panels4.0–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–9 panels4.4–5.0 kW DC

Compatible Solar Panels for SolaX Power A1-AC-3.8K-G2

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SolaX Power A1-AC-3.8K-G2
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V2–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V3–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V2–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V3–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V3–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V2–6 per string (-10°C)Verify Pair

Engineering FAQ — SolaX Power A1-AC-3.8K-G2

What size circuit breaker does the SolaX Power A1-AC-3.8K-G2 require under NEC 705.12?
At 3.81 kW continuous AC output on 240V (15.9A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SolaX Power A1-AC-3.8K-G2?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.81 kW unit with 4.19 kW to 5.14 kW DC of solar modules without exceeding 450V cold Voc.

More SolaX Power Inverters

A1-Micro 500P (0.506 kW)A1-Micro 600P (0.594 kW)A1-HYB-3.8K-G2 (3.805 kW)A1-HYB-5.0K-G2 (5.003 kW)A1-AC-5.0K-G2 (5.03 kW)A1-Hybrid-6.0-US (5.57 kW)All SolaX Power Equipment →