SX CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

SolaX Power A1-Micro 450P (0.458 kW)

450 VA, 240 Vac, Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.458 kW
CEC Weighted Eff.
93.5%
MPPT / Max DC
30–45V / 45V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolaX Power A1-Micro 450P — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 30–45 Vdc 30V 45V MAX 45V PV DC INPUT ≤ 45V DC 0.458 kW · 93.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

SolaX Power A1-Micro 450P Electrical and Grid-Support Specifications
ManufacturerSolaX Power
Model Number (MPN)A1-Micro 450P
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.458 kW (458 W)
Nominal DC Input (Pdco)482 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency93.5%
MPPT Operating Window30 – 45 Vdc (NREL SAM Measured)
Max DC Input Voltage45 Vdc
Max DC Input Current12.7 A
Night Tare Loss0.06 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for A1-Micro 450P
Max Continuous AC Current1.9 A @ 240V
125% Continuous Duty Current2.4 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.5–0.62 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for A1-Micro 450P
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.87× DC/AC)
440W1 panel1:1 pairing (0.96× DC/AC)
550W1 panel1:1 pairing (1.20× DC/AC)

Compatible Solar Panels for SolaX Power A1-Micro 450P

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SolaX Power A1-Micro 450P
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.27 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.27 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.26 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.22 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.21 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 1.04 (1 panel/input)Verify Pair

Engineering FAQ — SolaX Power A1-Micro 450P

What size circuit breaker does the SolaX Power A1-Micro 450P require under NEC 705.12?
At 0.458 kW continuous AC output on 240V (1.9A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SolaX Power A1-Micro 450P?
As a 458W microinverter, it pairs 1:1 with panels rated roughly 481W to 664W STC.

More SolaX Power Inverters

A1-Fit-8.6-US (8.613 kW)A1-Micro 300P (0.32 kW)A1-Micro 400P (0.41 kW)A1-Micro 500P (0.506 kW)A1-Micro 600P (0.594 kW)A1-HYB-3.8K-G2 (3.805 kW)All SolaX Power Equipment →