SL CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Solis (Ginlong) S6-EH1P9.9K-H-US (9.99 kW)

9.9 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.99 kW
CEC Weighted Eff.
97%
MPPT / Max DC
230–450V / 450V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Solis (Ginlong) S6-EH1P9.9K-H-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 230–450 Vdc 230V 450V MAX 450V PV DC INPUT ≤ 450V DC 9.99 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Solis (Ginlong) S6-EH1P9.9K-H-US Electrical and Grid-Support Specifications
ManufacturerSolis (Ginlong)
Model Number (MPN)S6-EH1P9.9K-H-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.99 kW (9,990 W)
Nominal DC Input (Pdco)10,258 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window230 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current27 A
Night Tare Loss16.38 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for S6-EH1P9.9K-H-US
Max Continuous AC Current41.6 A @ 240V
125% Continuous Duty Current52.0 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.99–13.49 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for S6-EH1P9.9K-H-US
Panel ClassRecommended QtyDC Array / Ratio
400W27–34 panels10.8–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Compatible Solar Panels for Solis (Ginlong) S6-EH1P9.9K-H-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Solis (Ginlong) S6-EH1P9.9K-H-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Solis (Ginlong) S6-EH1P9.9K-H-US

What size circuit breaker does the Solis (Ginlong) S6-EH1P9.9K-H-US require under NEC 705.12?
At 9.99 kW continuous AC output on 240V (41.6A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Solis (Ginlong) S6-EH1P9.9K-H-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.99 kW unit with 10.99 kW to 13.49 kW DC of solar modules without exceeding 450V cold Voc.

More Solis (Ginlong) Inverters

1P9K-4G-US (9 kW)RHI-1P9K-HVES-5G (9.006 kW)S6-EH2P9.6K03-SV-YD-L-US (9.647 kW)1P10K-4G-US (10 kW)S6-EH1P10K-H-US (10.001 kW)RHI-1P10K-HVES-5G (10.005 kW)All Solis (Ginlong) Equipment →