Solis (Ginlong) 1P6K2-4G-US (6 kW)
6 kW, 240 Vac, 1-phase Utility Interactive Inverter, 2 channel. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
6 kW
CEC Weighted Eff.
97%
MPPT / Max DC
300–500V / 500V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Solis (Ginlong) |
|---|---|
| Model Number (MPN) | 1P6K2-4G-US |
| Inverter Topology | String Inverter |
| Continuous AC Power (Paco) | 6 kW (6,000 W) |
| Nominal DC Input (Pdco) | 6,182 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 300 – 500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 500 Vdc |
| Max DC Input Current | 17.2 A |
| Night Tare Loss | 3.5 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 25 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 31.3 A |
| Minimum Standard Breaker | 35 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (6.6–8.1 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 17–20 panels | 6.8–8.0 kW DC |
| 440W | 15–18 panels | 6.6–7.9 kW DC |
| 550W | 12–15 panels | 6.6–8.3 kW DC |
Compatible Solar Panels for Solis (Ginlong) 1P6K2-4G-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 8–8 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 8–8 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 8–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 9–9 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 9–9 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 7–7 per string (-10°C) | Verify Pair |
Engineering FAQ — Solis (Ginlong) 1P6K2-4G-US
What size circuit breaker does the Solis (Ginlong) 1P6K2-4G-US require under NEC 705.12?
At 6 kW continuous AC output on 240V (25A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Solis (Ginlong) 1P6K2-4G-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6 kW unit with 6.6 kW to 8.1 kW DC of solar modules without exceeding 500V cold Voc.