SL CEC-Listed · 240V ResidentialStringUL 1741-SB (3rd Ed.)

Solis (Ginlong) 1P7.6K-4G-US (7.6 kW)

7.6 kW, 240 Vac, 1-phase Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.6 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
200–500V / 500V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Solis (Ginlong) 1P7.6K-4G-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 200–500 Vdc 200V 500V MAX 500V PV DC INPUT ≤ 500V DC 7.6 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Solis (Ginlong) 1P7.6K-4G-US Electrical and Grid-Support Specifications
ManufacturerSolis (Ginlong)
Model Number (MPN)1P7.6K-4G-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)7.6 kW (7,600 W)
Nominal DC Input (Pdco)7,799 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window200 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current20.5 A
Night Tare Loss7 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 1P7.6K-4G-US
Max Continuous AC Current31.7 A @ 240V
125% Continuous Duty Current39.6 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.36–10.26 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 1P7.6K-4G-US
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Solis (Ginlong) 1P7.6K-4G-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Solis (Ginlong) 1P7.6K-4G-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–7 per string (-10°C)Verify Pair

Engineering FAQ — Solis (Ginlong) 1P7.6K-4G-US

What size circuit breaker does the Solis (Ginlong) 1P7.6K-4G-US require under NEC 705.12?
At 7.6 kW continuous AC output on 240V (31.7A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Solis (Ginlong) 1P7.6K-4G-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.6 kW unit with 8.36 kW to 10.26 kW DC of solar modules without exceeding 500V cold Voc.

More Solis (Ginlong) Inverters

RHI-1P6K-HVES-5G (6.004 kW)1P7K-4G-US (7 kW)RHI-1P7K-HVES-5G (7.006 kW)S6-EH1P7.6K-H-US (7.604 kW)1P8K-4G-US (8 kW)RHI-1P8K-HVES-5G (8.006 kW)All Solis (Ginlong) Equipment →