SO CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Solvari SVR-A11-240 (0.398 kW)

400 VA, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.398 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
22–55V / 55V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Solvari SVR-A11-240 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 22–55 Vdc 22V 55V MAX 55V PV DC INPUT ≤ 55V DC 0.398 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Solvari SVR-A11-240 Electrical and Grid-Support Specifications
ManufacturerSolvari
Model Number (MPN)SVR-A11-240
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.398 kW (398 W)
Nominal DC Input (Pdco)413 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window22 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage55 Vdc
Max DC Input Current11.8 A
Night Tare Loss0.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SVR-A11-240
Max Continuous AC Current1.7 A @ 240V
125% Continuous Duty Current2.1 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.44–0.54 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SVR-A11-240
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.01× DC/AC)
440W1 panel1:1 pairing (1.11× DC/AC)
550W1 panel1:1 pairing (1.38× DC/AC)

Compatible Solar Panels for Solvari SVR-A11-240

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Solvari SVR-A11-240
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.46 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.46 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.44 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.41 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.39 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 1.19 (1 panel/input)Verify Pair

Engineering FAQ — Solvari SVR-A11-240

What size circuit breaker does the Solvari SVR-A11-240 require under NEC 705.12?
At 0.398 kW continuous AC output on 240V (1.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Solvari SVR-A11-240?
As a 398W microinverter, it pairs 1:1 with panels rated roughly 418W to 577W STC.

More Solvari Inverters

SVR-A10-240 (0.346 kW)All Solvari Equipment →