SE CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

SPITZER ENERGY COMPANY SPZ-M800-S (0.723 kW)

0.720 kW, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.723 kW
CEC Weighted Eff.
96%
MPPT / Max DC
35–50V / 50V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SPITZER ENERGY COMPANY SPZ-M800-S — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 35–50 Vdc 35V 50V MAX 50V PV DC INPUT ≤ 50V DC 0.723 kW · 96% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

SPITZER ENERGY COMPANY SPZ-M800-S Electrical and Grid-Support Specifications
ManufacturerSPITZER ENERGY COMPANY
Model Number (MPN)SPZ-M800-S
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.723 kW (723 W)
Nominal DC Input (Pdco)753 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window35 – 50 Vdc (NREL SAM Measured)
Max DC Input Voltage50 Vdc
Max DC Input Current17.9 A
Night Tare Loss0.4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SPZ-M800-S
Max Continuous AC Current3 A @ 240V
125% Continuous Duty Current3.8 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.8–0.98 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SPZ-M800-S
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.55× DC/AC)
440W1 panel1:1 pairing (0.61× DC/AC)
550W1 panel1:1 pairing (0.76× DC/AC)

Engineering FAQ — SPITZER ENERGY COMPANY SPZ-M800-S

What size circuit breaker does the SPITZER ENERGY COMPANY SPZ-M800-S require under NEC 705.12?
At 0.723 kW continuous AC output on 240V (3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SPITZER ENERGY COMPANY SPZ-M800-S?
As a 723W microinverter, it pairs 1:1 with panels rated roughly 759W to 1048W STC.

More SPITZER ENERGY COMPANY Inverters