SS CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

SRNE Solar SEI-8K-UP (8.81 kW)

8 kW, 240 Vac Grid Support Utility Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.81 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
275–450V / 450V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SRNE Solar SEI-8K-UP — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 275–450 Vdc 275V 450V MAX 450V PV DC INPUT ≤ 450V DC 8.81 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

SRNE Solar SEI-8K-UP Electrical and Grid-Support Specifications
ManufacturerSRNE Solar
Model Number (MPN)SEI-8K-UP
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)8.81 kW (8,810 W)
Nominal DC Input (Pdco)9,185 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window275 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current25.3 A
Night Tare Loss73.1 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SEI-8K-UP
Max Continuous AC Current36.7 A @ 240V
125% Continuous Duty Current45.9 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (9.69–11.89 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SEI-8K-UP
Panel ClassRecommended QtyDC Array / Ratio
400W24–30 panels9.6–12.0 kW DC
440W22–27 panels9.7–11.9 kW DC
550W18–22 panels9.9–12.1 kW DC

Compatible Solar Panels for SRNE Solar SEI-8K-UP

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SRNE Solar SEI-8K-UP
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V11–11 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445445 W40.16 V10–10 per string (-10°C)Verify Pair

Engineering FAQ — SRNE Solar SEI-8K-UP

What size circuit breaker does the SRNE Solar SEI-8K-UP require under NEC 705.12?
At 8.81 kW continuous AC output on 240V (36.7A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SRNE Solar SEI-8K-UP?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.81 kW unit with 9.69 kW to 11.89 kW DC of solar modules without exceeding 450V cold Voc.

More SRNE Solar Inverters