SA CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Suzhou Ample ESS AP-L15K-SPUS (15.015 kW)

15.01 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
15.015 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
202–480V / 480V
NEC 705.12 Breaker
80A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Suzhou Ample ESS AP-L15K-SPUS — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 202–480 Vdc 202V 480V MAX 480V PV DC INPUT ≤ 480V DC 15.015 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 80A BRKR

Electrical & Grid-Support Datasheet

Suzhou Ample ESS AP-L15K-SPUS Electrical and Grid-Support Specifications
ManufacturerSuzhou Ample ESS
Model Number (MPN)AP-L15K-SPUS
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)15.015 kW (15,015 W)
Nominal DC Input (Pdco)15,596 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window202 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current41 A
Night Tare Loss10.08 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for AP-L15K-SPUS
Max Continuous AC Current62.6 A @ 240V
125% Continuous Duty Current78.3 A
Minimum Standard Breaker80 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (16.52–20.27 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for AP-L15K-SPUS
Panel ClassRecommended QtyDC Array / Ratio
400W41–51 panels16.4–20.4 kW DC
440W38–46 panels16.7–20.2 kW DC
550W30–37 panels16.5–20.4 kW DC

Compatible Solar Panels for Suzhou Ample ESS AP-L15K-SPUS

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Suzhou Ample ESS AP-L15K-SPUS
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Suzhou Ample ESS AP-L15K-SPUS

What size circuit breaker does the Suzhou Ample ESS AP-L15K-SPUS require under NEC 705.12?
At 15.015 kW continuous AC output on 240V (62.6A continuous), the 125% continuous duty rule requires a minimum 80A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Suzhou Ample ESS AP-L15K-SPUS?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 15.015 kW unit with 16.52 kW to 20.27 kW DC of solar modules without exceeding 480V cold Voc.

More Suzhou Ample ESS Inverters

AP-L8K-SPUS (7.981 kW)AP-L10K-SPUS (10.011 kW)AP-L12K-SPUS (12.014 kW)All Suzhou Ample ESS Equipment →