Tabuchi Electric THD-S55P3BB-US (5.519 kW)
5.5 kW, 240 Vac Grid Support Utility Interactive Hybrid Inverter with 3.3 kW Discharge Rate/20 kWh Storage Capacity. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
5.519 kW
CEC Weighted Eff.
94.5%
MPPT / Max DC
240–520V / 520V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Tabuchi Electric |
|---|---|
| Model Number (MPN) | THD-S55P3BB-US |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 5.519 kW (5,519 W) |
| Nominal DC Input (Pdco) | 5,822 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 94.5% |
| MPPT Operating Window | 240 – 520 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 520 Vdc |
| Max DC Input Current | 15.3 A |
| Night Tare Loss | 10.1 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 23 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 28.8 A |
| Minimum Standard Breaker | 30 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (6.07–7.45 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 15–19 panels | 6.0–7.6 kW DC |
| 440W | 14–17 panels | 6.2–7.5 kW DC |
| 550W | 11–14 panels | 6.0–7.7 kW DC |
Compatible Solar Panels for Tabuchi Electric THD-S55P3BB-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 7–9 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 7–9 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 7–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–9 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–9 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–7 per string (-10°C) | Verify Pair |
Engineering FAQ — Tabuchi Electric THD-S55P3BB-US
What size circuit breaker does the Tabuchi Electric THD-S55P3BB-US require under NEC 705.12?
At 5.519 kW continuous AC output on 240V (23A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Tabuchi Electric THD-S55P3BB-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.519 kW unit with 6.07 kW to 7.45 kW DC of solar modules without exceeding 520V cold Voc.