TE CEC-Listed · 240V ResidentialHybridBattery Hybrid

Tabuchi Electric THE-S55P3BB-USW (5.519 kW)

5.5 kW, 240 Vac Grid Support Utility Interactive Hybrid Inverter with 4.0 kW Discharge Rate/20 kWh Storage Capacity. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.519 kW
CEC Weighted Eff.
94.5%
MPPT / Max DC
240–520V / 520V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Tabuchi Electric THE-S55P3BB-USW — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 240–520 Vdc 240V 520V MAX 520V PV DC INPUT ≤ 520V DC 5.519 kW · 94.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

Tabuchi Electric THE-S55P3BB-USW Electrical and Grid-Support Specifications
ManufacturerTabuchi Electric
Model Number (MPN)THE-S55P3BB-USW
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.519 kW (5,519 W)
Nominal DC Input (Pdco)5,822 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency94.5%
MPPT Operating Window240 – 520 Vdc (NREL SAM Measured)
Max DC Input Voltage520 Vdc
Max DC Input Current15.3 A
Night Tare Loss10.1 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for THE-S55P3BB-USW
Max Continuous AC Current23 A @ 240V
125% Continuous Duty Current28.8 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.07–7.45 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for THE-S55P3BB-USW
Panel ClassRecommended QtyDC Array / Ratio
400W15–19 panels6.0–7.6 kW DC
440W14–17 panels6.2–7.5 kW DC
550W11–14 panels6.0–7.7 kW DC

Compatible Solar Panels for Tabuchi Electric THE-S55P3BB-USW

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Tabuchi Electric THE-S55P3BB-USW
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–7 per string (-10°C)Verify Pair

Engineering FAQ — Tabuchi Electric THE-S55P3BB-USW

What size circuit breaker does the Tabuchi Electric THE-S55P3BB-USW require under NEC 705.12?
At 5.519 kW continuous AC output on 240V (23A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Tabuchi Electric THE-S55P3BB-USW?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.519 kW unit with 6.07 kW to 7.45 kW DC of solar modules without exceeding 520V cold Voc.

More Tabuchi Electric Inverters

THD-S55P3B-US (5.519 kW)All Tabuchi Electric Equipment →