Tigo Energy official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Tigo Energy TSI-3.0K-US (3.095 kW)

3.095 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.095 kW
CEC Weighted Eff.
97%
MPPT / Max DC
125–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Tigo Energy TSI-3.0K-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 125–480 Vdc 125V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.095 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

Tigo Energy TSI-3.0K-US Electrical and Grid-Support Specifications
ManufacturerTigo Energy
Model Number (MPN)TSI-3.0K-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.095 kW (3,095 W)
Nominal DC Input (Pdco)3,184 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window125 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current8.4 A
Night Tare Loss1.59 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for TSI-3.0K-US
Max Continuous AC Current12.9 A @ 240V
125% Continuous Duty Current16.1 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (3.4–4.18 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for TSI-3.0K-US
Panel ClassRecommended QtyDC Array / Ratio
400W9–10 panels3.6–4.0 kW DC
440W8–10 panels3.5–4.4 kW DC
550W6–8 panels3.3–4.4 kW DC

Compatible Solar Panels for Tigo Energy TSI-3.0K-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Tigo Energy TSI-3.0K-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–6 per string (-10°C)Verify Pair

Engineering FAQ — Tigo Energy TSI-3.0K-US

What size circuit breaker does the Tigo Energy TSI-3.0K-US require under NEC 705.12?
At 3.095 kW continuous AC output on 240V (12.9A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Tigo Energy TSI-3.0K-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.095 kW unit with 3.4 kW to 4.18 kW DC of solar modules without exceeding 480V cold Voc.

More Tigo Energy Inverters

TSI-9.0K-US (9.063 kW)TSI-10.0K-US (10.082 kW)TSI-11.4K-US (11.52 kW)TSI-3.8K-US (3.888 kW)TSI-5.0K-US (4.943 kW)TSI-6.0K-US (5.918 kW)All Tigo Energy Equipment →