Tigo Energy official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Tigo Energy TSI-7.6K-US (7.524 kW)

7.524 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.524 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
212–480V / 480V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Tigo Energy TSI-7.6K-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 212–480 Vdc 212V 480V MAX 480V PV DC INPUT ≤ 480V DC 7.524 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Tigo Energy TSI-7.6K-US Electrical and Grid-Support Specifications
ManufacturerTigo Energy
Model Number (MPN)TSI-7.6K-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.524 kW (7,524 W)
Nominal DC Input (Pdco)7,742 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97.5%
MPPT Operating Window212 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current20.4 A
Night Tare Loss1.59 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for TSI-7.6K-US
Max Continuous AC Current31.4 A @ 240V
125% Continuous Duty Current39.3 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.28–10.16 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for TSI-7.6K-US
Panel ClassRecommended QtyDC Array / Ratio
400W21–25 panels8.4–10.0 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–18 panels8.3–9.9 kW DC

Compatible Solar Panels for Tigo Energy TSI-7.6K-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Tigo Energy TSI-7.6K-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Tigo Energy TSI-7.6K-US

What size circuit breaker does the Tigo Energy TSI-7.6K-US require under NEC 705.12?
At 7.524 kW continuous AC output on 240V (31.4A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Tigo Energy TSI-7.6K-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.524 kW unit with 8.28 kW to 10.16 kW DC of solar modules without exceeding 480V cold Voc.

More Tigo Energy Inverters

TSI-3.8K-US (3.888 kW)TSI-5.0K-US (4.943 kW)TSI-6.0K-US (5.918 kW)TSI-8.2K-US (8.251 kW)TSI-9.0K-US (9.063 kW)TSI-10.0K-US (10.082 kW)All Tigo Energy Equipment →