TS CEC-Listed · 240V ResidentialMicroinverter

TSUNESS TSOL-M1600P (1.551 kW)

1.5 kW, 240 Vac Grid Support Utility Interactive Microinverters. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.551 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
36–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
TSUNESS TSOL-M1600P — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 36–48 Vdc 36V 48V MAX 48V PV DC INPUT ≤ 48V DC 1.551 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

TSUNESS TSOL-M1600P Electrical and Grid-Support Specifications
ManufacturerTSUNESS
Model Number (MPN)TSOL-M1600P
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.551 kW (1,551 W)
Nominal DC Input (Pdco)1,610 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window36 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current38.3 A
Night Tare Loss0.03 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for TSOL-M1600P
Max Continuous AC Current6.5 A @ 240V
125% Continuous Duty Current8.1 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.71–2.09 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for TSOL-M1600P
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.26× DC/AC)
440W1 panel1:1 pairing (0.28× DC/AC)
550W1 panel1:1 pairing (0.35× DC/AC)

Engineering FAQ — TSUNESS TSOL-M1600P

What size circuit breaker does the TSUNESS TSOL-M1600P require under NEC 705.12?
At 1.551 kW continuous AC output on 240V (6.5A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the TSUNESS TSOL-M1600P?
As a 1551W microinverter, it pairs 1:1 with panels rated roughly 1629W to 2249W STC.