CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery HybridEstimated MPPT — Verify Manufacturer Datasheet
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 15KW (14.79 kW)
15 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
14.79 kW
CEC Weighted Eff.
97%
MPPT / Max DC
120–500V / 600VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
80A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | VOLTRONIC POWER TECHNOLOGY (SHENZHEN) |
|---|---|
| Model Number (MPN) | InfiniSolar WP LV 15KW |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 14.79 kW (14,790 W) |
| Nominal DC Input (Pdco) | 15,247 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 240V, 120V |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 120 – 500 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design |
| Max DC Input Voltage | 600 Vdc |
| Max DC Input Current | 47.2 A |
| Night Tare Loss | 42 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 61.6 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 77.0 A |
| Minimum Standard Breaker | 80 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (16.27–19.97 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 41–50 panels | 16.4–20.0 kW DC |
| 440W | 37–45 panels | 16.3–19.8 kW DC |
| 550W | 30–36 panels | 16.5–19.8 kW DC |
Compatible Solar Panels for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 15KW
Test any of 3,007 panels with this inverter →Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (120–500 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 4–10 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 4–10 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 4–10 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 4–10 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 4–11 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 3–8 per string (-10°C) | Verify Pair |
Engineering FAQ — VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 15KW
What size circuit breaker does the VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 15KW require under NEC 705.12?
At 14.79 kW continuous AC output on 240V (61.6A continuous), the 125% continuous duty rule requires a minimum 80A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the VOLTRONIC POWER TECHNOLOGY (SHENZHEN) InfiniSolar WP LV 15KW?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 14.79 kW unit with 16.27 kW to 19.97 kW DC of solar modules without exceeding 600V cold Voc.