WD CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Wanbang Digital Energy SI104LULA00 (9.58 kW)

9.6 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.58 kW
CEC Weighted Eff.
97%
MPPT / Max DC
320–480V / 480V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Wanbang Digital Energy SI104LULA00 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 320–480 Vdc 320V 480V MAX 480V PV DC INPUT ≤ 480V DC 9.58 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

Wanbang Digital Energy SI104LULA00 Electrical and Grid-Support Specifications
ManufacturerWanbang Digital Energy
Model Number (MPN)SI104LULA00
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.58 kW (9,580 W)
Nominal DC Input (Pdco)9,914 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window320 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current27.5 A
Night Tare Loss5.42 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SI104LULA00
Max Continuous AC Current39.9 A @ 240V
125% Continuous Duty Current49.9 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.54–12.93 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SI104LULA00
Panel ClassRecommended QtyDC Array / Ratio
400W26–32 panels10.4–12.8 kW DC
440W24–29 panels10.6–12.8 kW DC
550W19–24 panels10.4–13.2 kW DC

Compatible Solar Panels for Wanbang Digital Energy SI104LULA00

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Wanbang Digital Energy SI104LULA00
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
SEG Solar SEG-560-BTC-HV560 W48.81 V9–9 per string (-10°C)Verify Pair
Silfab Solar SIL-540XM540 W47.95 V9–9 per string (-10°C)Verify Pair
Canadian Solar CS6.2-48TM-430H430 W35 V13–13 per string (-10°C)Verify Pair
REC Solar REC430AA Pure 2430 W49 V9–9 per string (-10°C)Verify Pair

Engineering FAQ — Wanbang Digital Energy SI104LULA00

What size circuit breaker does the Wanbang Digital Energy SI104LULA00 require under NEC 705.12?
At 9.58 kW continuous AC output on 240V (39.9A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Wanbang Digital Energy SI104LULA00?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.58 kW unit with 10.54 kW to 12.93 kW DC of solar modules without exceeding 480V cold Voc.