Xiamen Kehua Digital Energy Tech iStoragE2A 10000 (9.956 kW)
10 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
9.956 kW
CEC Weighted Eff.
97%
MPPT / Max DC
300–440V / 440V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Xiamen Kehua Digital Energy Tech |
|---|---|
| Model Number (MPN) | iStoragE2A 10000 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 9.956 kW (9,956 W) |
| Nominal DC Input (Pdco) | 10,243 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 300 – 440 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 440 Vdc |
| Max DC Input Current | 27.7 A |
| Night Tare Loss | 2.5 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 41.5 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 51.9 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (10.95–13.44 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 27–34 panels | 10.8–13.6 kW DC |
| 440W | 25–31 panels | 11.0–13.6 kW DC |
| 550W | 20–24 panels | 11.0–13.2 kW DC |
Compatible Solar Panels for Xiamen Kehua Digital Energy Tech iStoragE2A 10000
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Maxeon / SunPower SPR-MAX3-430 | 430 W | 81.36 V | 5–5 per string (-10°C) | Verify Pair |
Engineering FAQ — Xiamen Kehua Digital Energy Tech iStoragE2A 10000
What size circuit breaker does the Xiamen Kehua Digital Energy Tech iStoragE2A 10000 require under NEC 705.12?
At 9.956 kW continuous AC output on 240V (41.5A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Xiamen Kehua Digital Energy Tech iStoragE2A 10000?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.956 kW unit with 10.95 kW to 13.44 kW DC of solar modules without exceeding 440V cold Voc.