Reference US Solar ConfigurationColorado (CO)1:1 Retail

10.4 kW Mission + Enphase + Battery Solar Kit (Colorado)

Texas-Built Panels + Smart Whole-Home Storage · Colorado High-Altitude Cold Voc. Reference Bill of Materials pairing 25× Mission Solar MSX10-415HN0B {C} with 25× Enphase Energy IQ8M-72-2-US and 1× FranklinWH aPower 2 (APR-15KWH-US).

System Size
10.38 kW DC / 8.12 kW AC
Est. Annual Yield
16,549 kWh
Est. Savings (CO)
$2,374/yr
Turnkey Cash Est.
$43,483Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · CO RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (25×) Mission Solar MSX10-415… 10.38 kW DC STC DC 2. INVERTER (25×) Enphase Energy IQ8M-72-2-… 8.12 kW AC · 240V 45A 3. MAIN PANEL & GRID 225A Busbar · NEC 705.12 45A Backfeed · CO Grid 4. HOME ENERGY STORAGE (1×) FranklinWH aPower 2 (APR-15KWH-… · 15.0 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 10.4 kW Mission + Enphase + Battery Solar Kit (Colorado)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesMission SolarMSX10-415HN0B {C}25×10.38 kW DC (522 sq ft)Panel Specs →
InverterEnphase EnergyIQ8M-72-2-US25×8.12 kW AC · 1.28× DC/AC · 45A BreakerInverter Specs →
Energy StorageFranklinWHaPower 2 (APR-15KWH-US)1×15 kWh usable capacityBattery Specs →

Cost & Sizing Notes for Colorado

Modeled at Colorado’s average residential electricity rate (15.1¢/kWh) under 1:1 Retail, this 10.38 kW DC / 8.12 kW AC array produces an estimated 16,549 kWh/year (~$2,374/yr gross bill offset, simple pre-incentive payback ~18.3 years at the $43,483 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 522 sq ft, with a 1.28× DC/AC ratio and a 45A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $43,483 estimate for this 10.38 kW Colorado solar kit?
The $43,483 figure is a pre-incentive 2026 turnkey cash estimate covering 25× Mission Solar MSX10-415HN0B {C} panels, 25× Enphase Energy IQ8M-72-2-US, 1× FranklinWH aPower 2 (APR-15KWH-US) (15 kWh), racking, permitting, and licensed installation in Colorado. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 10.38 kW solar kit fit on a standard 225A electrical panel under NEC 705.12?
At 8.12 kW continuous AC output, the inverter requires a 45A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 45A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference Colorado Solar Kits

10.4 kW Qcells + Enphase + Battery Solar Kit (Colorado)11.0 kW REC + Tesla + Battery Solar Kit (Colorado)10.6 kW Silfab + Sol-Ark + Battery Solar Kit (Colorado)10.6 kW JinkoSolar + EG4 + Battery Solar Kit (Colorado)All 120 Kits →