Reference US Solar ConfigurationTexas (TX)Utility-Dependent

8.4 kW LONGi + Solis + Battery Solar Kit (Texas)

High-Efficiency Value Hybrid Backup · Texas ERCOT Whole-Home. Reference Bill of Materials pairing 20× LONGi Solar LR5-54HABD-420M with 1× Solis (Ginlong) S6-EH1P7.6K-H-US and 1× Fortress Power DuraRack DC energy storage system-10.8P2.

System Size
8.4 kW DC / 7.6 kW AC
Est. Annual Yield
13,153 kWh
Est. Savings (TX)
$1,759/yr
Turnkey Cash Est.
$32,296Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · TX RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (20×) LONGi Solar LR5-54HABD-… 8.40 kW DC STC DC 2. INVERTER (1×) Solis (Ginlong) S6-EH1P7.… 7.60 kW AC · 240V 40A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 40A Backfeed · TX Grid 4. HOME ENERGY STORAGE (1×) Fortress Power DuraRack DC ener… · 10.8 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 8.4 kW LONGi + Solis + Battery Solar Kit (Texas)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesLONGi SolarLR5-54HABD-420M20×8.4 kW DC (409 sq ft)Panel Specs →
InverterSolis (Ginlong)S6-EH1P7.6K-H-US1×7.6 kW AC · 1.11× DC/AC · 40A BreakerInverter Specs →
Energy StorageFortress PowerDuraRack DC energy storage system-10.8P21×10.8 kWh usable capacityBattery Specs →

Cost & Sizing Notes for Texas

Modeled at Texas’s average residential electricity rate (15.2¢/kWh) under Utility-Dependent, this 8.4 kW DC / 7.6 kW AC array produces an estimated 13,153 kWh/year (~$1,759/yr gross bill offset, simple pre-incentive payback ~18.4 years at the $32,296 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 409 sq ft, with a 1.11× DC/AC ratio and a 40A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $32,296 estimate for this 8.4 kW Texas solar kit?
The $32,296 figure is a pre-incentive 2026 turnkey cash estimate covering 20× LONGi Solar LR5-54HABD-420M panels, 1× Solis (Ginlong) S6-EH1P7.6K-H-US, 1× Fortress Power DuraRack DC energy storage system-10.8P2 (10.8 kWh), racking, permitting, and licensed installation in Texas. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 8.4 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 7.6 kW continuous AC output, the inverter requires a 40A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 40A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference Texas Solar Kits

8.3 kW Qcells + Enphase + Battery Solar Kit (Texas)11.0 kW REC + Tesla + Battery Solar Kit (Texas)8.8 kW Silfab + Sol-Ark + Battery Solar Kit (Texas)8.8 kW JinkoSolar + EG4 + Battery Solar Kit (Texas)All 120 Kits →