Reference US Solar ConfigurationIllinois (IL)Avoided Cost

8.5 kW Trina + Hoymiles + Battery Solar Kit (Illinois)

Cost-Optimized Microinverter + Heavy LFP · Illinois SREC Value. Reference Bill of Materials pairing 19× Trina Solar TSM-445NEG9RH.25 with 19× Hoymiles HMS-400-1A-NA and 1× Fortress Power eForce DC energy storage system-9.6P1-0.

System Size
8.46 kW DC / 6.88 kW AC
Est. Annual Yield
10,598 kWh
Est. Savings (IL)
$1,137/yr
Turnkey Cash Est.
$34,645Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · IL RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (19×) Trina Solar TSM-445NEG9… 8.46 kW DC STC DC 2. INVERTER (19×) Hoymiles HMS-400-1A-NA 6.88 kW AC · 240V 40A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 40A Backfeed · IL Grid 4. HOME ENERGY STORAGE (1×) Fortress Power eForce DC energy… · 9.6 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 8.5 kW Trina + Hoymiles + Battery Solar Kit (Illinois)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesTrina SolarTSM-445NEG9RH.2519×8.46 kW DC (405 sq ft)Panel Specs →
InverterHoymilesHMS-400-1A-NA19×6.88 kW AC · 1.23× DC/AC · 40A BreakerInverter Specs →
Energy StorageFortress PowereForce DC energy storage system-9.6P1-01×9.6 kWh usable capacityBattery Specs →

Cost & Sizing Notes for Illinois

Modeled at Illinois’s average residential electricity rate (16.5¢/kWh) under Avoided Cost, this 8.46 kW DC / 6.88 kW AC array produces an estimated 10,598 kWh/year (~$1,137/yr gross bill offset, simple pre-incentive payback ~30.5 years at the $34,645 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 405 sq ft, with a 1.23× DC/AC ratio and a 40A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $34,645 estimate for this 8.46 kW Illinois solar kit?
The $34,645 figure is a pre-incentive 2026 turnkey cash estimate covering 19× Trina Solar TSM-445NEG9RH.25 panels, 19× Hoymiles HMS-400-1A-NA, 1× Fortress Power eForce DC energy storage system-9.6P1-0 (9.6 kWh), racking, permitting, and licensed installation in Illinois. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 8.46 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 6.88 kW continuous AC output, the inverter requires a 40A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 40A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.