Reference US Solar ConfigurationIllinois (IL)Avoided Cost

8.6 kW Canadian + SolarEdge Solar Kit (Illinois)

DC-Coupled Optimized Roof + Battery · Illinois SREC Value. Reference Bill of Materials pairing 20× Canadian Solar CS6.2-48TM-430H with 1× SolarEdge SE7600H-US.

System Size
8.6 kW DC / 7.62 kW AC
Est. Annual Yield
10,773 kWh
Est. Savings (IL)
$1,155/yr
Turnkey Cash Est.
$25,370Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · IL RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (20×) Canadian Solar CS6.2-48… 8.60 kW DC STC DC 2. INVERTER (1×) SolarEdge SE7600H-US 7.62 kW AC · 240V 40A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 40A Backfeed · IL Grid GRID-TIED SOLAR ONLY · ADD BATTERY IN STEP 3 FOR BACKUP
3. Battery Storage

Grid-Tied Solar Only

Optimized for 1:1 net-metering payback. Want storm backup? Clone this kit and add a UL 9540 battery in Step 3.

Add Battery to This Kit →

Reference Bill of Materials & NEC Summary

Bill of Materials for 8.6 kW Canadian + SolarEdge Solar Kit (Illinois)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesCanadian SolarCS6.2-48TM-430H20×8.6 kW DC (415 sq ft)Panel Specs →
InverterSolarEdgeSE7600H-US1×7.62 kW AC · 1.13× DC/AC · 40A BreakerInverter Specs →

Cost & Sizing Notes for Illinois

Modeled at Illinois’s average residential electricity rate (16.5¢/kWh) under Avoided Cost, this 8.6 kW DC / 7.62 kW AC array produces an estimated 10,773 kWh/year (~$1,155/yr gross bill offset, simple pre-incentive payback ~22.0 years at the $25,370 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 415 sq ft, with a 1.13× DC/AC ratio and a 40A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $25,370 estimate for this 8.6 kW Illinois solar kit?
The $25,370 figure is a pre-incentive 2026 turnkey cash estimate covering 20× Canadian Solar CS6.2-48TM-430H panels, 1× SolarEdge SE7600H-US, racking, permitting, and licensed installation in Illinois. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 8.6 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 7.62 kW continuous AC output, the inverter requires a 40A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 40A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.