FS CEC-Listed · ResidentialUL 61730

First Solar FS-6430A-P-B-2 (430W)

430 W, 268 cell CdTe thin film module with anti-reflective coating, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
430W / 408W
Efficiency
17.06%
Voc / Vmp
225.48V / 176.47V
Max String (600V)
2 @ −10°C
System Design Actions
Match Compatible Inverters →
First Solar FS-6430A-P-B-2 — Illustrative category photo — not this exact model · Real thin-film CdTe photovoltaic solar array
Illustrative category photo — not this exact model · Real thin-film CdTe photovoltaic solar arrayWikimedia Commons — File:NREL Array.jpg (Public domain)
MODULE FOOTPRINT (108 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 243.32V Isc 2.66A MPP 430W (176.47V · 2.44A) Voc 225.48V DC Voltage (V) · Efficiency 17.06%

Electrical & Thermal Specifications (STC)

First Solar FS-6430A-P-B-2 Electrical and Mechanical Specifications
ManufacturerFirst Solar
Model Number (MPN)FS-6430A-P-B-2
Cell TechnologyThin Film · 108 cells
Nameplate Power (Pmax STC)430 W
Real-World Output (PTC)408 W (94.9% of STC)
Module Efficiency17.06% (170.6 W/m²)
Open-Circuit Voltage (Voc)225.48 V
Maximum Power Voltage (Vmp)176.47 V
Short-Circuit Current (Isc)2.66 A (NEC 1.25× = 3.33 A)
Maximum Power Current (Imp)2.44 A
Temp. Coeff. Power (γPmax)-0.229 %/°C
Temp. Coeff. Voltage (βVoc)-0.226 %/°C
Temp. Coeff. Current (αIsc)+0.033 %/°C
Nominal Cell Temp (NOCT)47 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet)
Surface Area2.52 m² (27.1 sq ft) (Est.)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.226%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for FS-6430A-P-B-2
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
225.48 V24
0°C / 32°F
Freezing / Mild Winter
238.22 V24
-10°C / 14°F
TX / Southeast / Mid-Atlantic
243.32 V24
-20°C / -4°F
Northeast / Midwest Winter
248.41 V24
-30°C / -22°F
Northern Plains / Mountain
253.51 V23

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using FS-6430A-P-B-2
Target SizePanels NeededActual DCRoof Footprint
6 kW14 panels6.02 kW380 sq ft (35.3 m²)
8 kW19 panels8.17 kW515 sq ft (47.9 m²)
10 kW24 panels10.32 kW651 sq ft (60.5 m²)
12 kW28 panels12.04 kW760 sq ft (70.6 m²)

Engineering FAQ — First Solar FS-6430A-P-B-2

How many First Solar FS-6430A-P-B-2 panels can fit in one 600V string?
At -10°C (14°F) ambient, the FS-6430A-P-B-2 open-circuit voltage rises from 225.48V to 243.32V (using βVoc -0.226%/°C), allowing up to 2 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the First Solar FS-6430A-P-B-2?
Rated at 430W STC, the FS-6430A-P-B-2 carries a 408W PTC rating (94.9% PTC/STC ratio) and 17.06% module efficiency across 2.52 m² (27.1 sq ft).
Is the First Solar FS-6430A-P-B-2 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More First Solar Solar Panels

FS-6435-P-B (435W)FS-6435-P-B-2 (435W)FS-6430A-P-B (430W)FS-6430-P-B-2 (430W)FS-6425A-P-B (425W)FS-6425-P-B-2 (425W)All First Solar Equipment →