First Solar FS-6480A-P-I (480W)
480 W, 268 cell CdTe thin film module with anti-reflective coating, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
480W / 452.3W
Efficiency
19.05%
Voc / Vmp
225.4V / 192.8V
Max String (600V)
2 @ −10°C
System Design Actions
Match Compatible Inverters →
Electrical & Thermal Specifications (STC)
| Manufacturer | First Solar |
|---|---|
| Model Number (MPN) | FS-6480A-P-I |
| Cell Technology | CdTe · 108 cells |
| Nameplate Power (Pmax STC) | 480 W |
| Real-World Output (PTC) | 452.3 W (94.2% of STC) |
| Module Efficiency | 19.05% (190.5 W/m²) |
| Open-Circuit Voltage (Voc) | 225.4 V |
| Maximum Power Voltage (Vmp) | 192.8 V |
| Short-Circuit Current (Isc) | 2.62 A (NEC 1.25× = 3.28 A) |
| Maximum Power Current (Imp) | 2.49 A |
| Temp. Coeff. Power (γPmax) | -0.272 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.277 %/°C |
| Temp. Coeff. Current (αIsc) | +0.056 %/°C |
| Nominal Cell Temp (NOCT) | 46.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.52 m² (27.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.277%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 225.4 V | 2 | 4 |
| 0°C / 32°F Freezing / Mild Winter | 241.01 V | 2 | 4 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 247.25 V | 2 | 4 |
| -20°C / -4°F Northeast / Midwest Winter | 253.5 V | 2 | 3 |
| -30°C / -22°F Northern Plains / Mountain | 259.74 V | 2 | 3 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.24 kW | 353 sq ft (32.8 m²) |
| 8 kW | 17 panels | 8.16 kW | 461 sq ft (42.8 m²) |
| 10 kW | 21 panels | 10.08 kW | 570 sq ft (52.9 m²) |
| 12 kW | 25 panels | 12.00 kW | 678 sq ft (63.0 m²) |
Engineering FAQ — First Solar FS-6480A-P-I
How many First Solar FS-6480A-P-I panels can fit in one 600V string?
At -10°C (14°F) ambient, the FS-6480A-P-I open-circuit voltage rises from 225.4V to 247.25V (using βVoc -0.277%/°C), allowing up to 2 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the First Solar FS-6480A-P-I?
Rated at 480W STC, the FS-6480A-P-I carries a 452.3W PTC rating (94.2% PTC/STC ratio) and 19.05% module efficiency across 2.52 m² (27.1 sq ft).
Is the First Solar FS-6480A-P-I listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.