First Solar FS-7520A-TR1 (520W)
520 W, 268 cell CdTe thin film module with anti-reflective coating, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
520W / 483.7W
Efficiency
18.57%
Voc / Vmp
225.6V / 185.2V
Max String (600V)
2 @ −10°C
System Design Actions
Match Compatible Inverters →
Electrical & Thermal Specifications (STC)
| Manufacturer | First Solar |
|---|---|
| Model Number (MPN) | FS-7520A-TR1 |
| Cell Technology | CdTe · 108 cells |
| Nameplate Power (Pmax STC) | 520 W |
| Real-World Output (PTC) | 483.7 W (93% of STC) |
| Module Efficiency | 18.57% (185.7 W/m²) |
| Open-Circuit Voltage (Voc) | 225.6 V |
| Maximum Power Voltage (Vmp) | 185.2 V |
| Short-Circuit Current (Isc) | 3.04 A (NEC 1.25× = 3.80 A) |
| Maximum Power Current (Imp) | 2.81 A |
| Temp. Coeff. Power (γPmax) | -0.295 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.272 %/°C |
| Temp. Coeff. Current (αIsc) | +0.048 %/°C |
| Nominal Cell Temp (NOCT) | 48.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.8 m² (30.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.272%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 225.6 V | 2 | 4 |
| 0°C / 32°F Freezing / Mild Winter | 240.94 V | 2 | 4 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 247.08 V | 2 | 4 |
| -20°C / -4°F Northeast / Midwest Winter | 253.21 V | 2 | 3 |
| -30°C / -22°F Northern Plains / Mountain | 259.35 V | 2 | 3 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.24 kW | 362 sq ft (33.6 m²) |
| 8 kW | 16 panels | 8.32 kW | 482 sq ft (44.8 m²) |
| 10 kW | 20 panels | 10.40 kW | 603 sq ft (56.0 m²) |
| 12 kW | 24 panels | 12.48 kW | 723 sq ft (67.2 m²) |
Engineering FAQ — First Solar FS-7520A-TR1
How many First Solar FS-7520A-TR1 panels can fit in one 600V string?
At -10°C (14°F) ambient, the FS-7520A-TR1 open-circuit voltage rises from 225.6V to 247.08V (using βVoc -0.272%/°C), allowing up to 2 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the First Solar FS-7520A-TR1?
Rated at 520W STC, the FS-7520A-TR1 carries a 483.7W PTC rating (93% PTC/STC ratio) and 18.57% module efficiency across 2.8 m² (30.1 sq ft).
Is the First Solar FS-7520A-TR1 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.