Residential Planning · IECC Climate Zones · SEER2 & R-454B (2026)

Preliminary Heat Pump Load Estimator

Avoid costly HVAC oversizing: run a preliminary residential cooling/heating BTU estimate by ZIP climate zone, envelope tightness, and ceiling height, and compare 15-year operating costs against gas, oil, or propane.

Resolved to Texas (IECC 2A–3B). Design temperatures: 95°F cooling / 26°F heating.

Ceiling Heighttaller adds volume
Envelope Vintage
Window Tier
Existing Heating Fuel
Target SEER2cooling efficiency rating
Preliminary Heat Pump Load EstimatorHeat Pump Conversion
Cooling Load
28,500 BTU/h
SHR 0.74 · 2.4 ton
Heating Design Load
23,600 BTU/h
at 26°F outdoor
Recommended Tonnage
2.5 ton
Sized to the cooling load
Est. Installed Range (TX)
$7,600–$15,200
SEER2 18.0 lands near $12,160 · state profile, size-adjusted

System Recommendation

Heat Pump Conversion

Heat pump conversion: no cold-climate premium required

Heat from the heat pump costs $15.01/MMBtu against $18.33/MMBtu from the natural gas furnace, in a climate mild enough that standard equipment holds capacity.

Climate
IECC 2.5A (2A–3B) · 2,250 HDD65
Heat cost, seasonal
$15.01/MMBtu from the heat pump vs $18.33 from existing heat
Heat cost, design day
$22.27/MMBtu at SEER2 18.0 and 2.0 COP
Capacity at design
30,000 BTU/h delivered vs 23,600 BTU/h needed
Backup heat
None needed at the design point

15-Year Operating Cost

Existing gaslegacy 10.5 SEER2 AC$20,465$1,364/yrHeat pumpSEER2 15.2 · minimum$16,134$1,076/yrHeat pumpSEER2 18.0 · two-stage$13,550$903/yrHeat pumpSEER2 20.0 · inverter$11,954$797/yr
  • Selected SEER2 18.0 saves $6,915 over 15 years vs today.
  • Stepping up from SEER2 15.2 to 18.0 saves $2,584 over 15 years ($172/yr) for about $4,560 more installed — does not pay back on energy savings alone within 15 years.

What Went Into the Numbers

Climate
2,200 full-load cooling hours and 2,250 heating degree-days per year at zone 2.5A
Envelope
1980–2005 Average: wall U 0.085, ceiling U 0.04, 0.55 ACH (165 CFM), 10% duct loss, 240 sq ft of glass
Equipment
SEER2 18.0 / HSPF2 9: seasonal COP 2.97 in this zone, 100% of rated capacity at design
Prices
Electricity 15.2¢/kWh (TX profile) and $1.54/therm TX profile; held flat for 15 years, no discounting
Installed cost
Texas profile of $7,600–$15,200, indexed to a 2.5-ton system and scaled by capacity and tier

Where the Load Comes From

ComponentCooling (BTU/h)Heating (BTU/h)
Walls (conduction)4,9007,900
Ceiling (vented attic)2,1001,600
Floor (ground coupling)—1,000
Windows (conduction + solar)7,3003,200
Infiltration3,5007,800
Internal gains1,400—
Duct losses1,9002,100
Latent (humidity removal)7,400—
Total design load28,50023,600
R-454B transition: what changes on a 2025–2026 quote
  • Since January 1, 2025, EPA rules under the AIM Act bar manufacturing new residential central AC and heat-pump systems with high-GWP refrigerants such as R-410A. New systems ship with R-454B (GWP 466) or R-32 (GWP 675).
  • Both are A2L “mildly flammable” refrigerants: expect an A2L-rated outdoor disconnect, a minimum room-volume check (or mitigation design) for indoor units, and an A2L-trained installer.
  • A new R-454B condenser cannot be matched to an existing R-410A indoor coil — budget to replace the coil or air handler in the same project.
  • R-410A equipment manufactured before 2025 can still be installed: an amended EPA final rule effective July 27, 2026 removed the old January 1, 2026 installation deadline, so remaining stock is legal until it sells out. That stock is finite, and some states (notably New York) restrict new R-410A installs under their own law.

Ask every bidder to list the refrigerant and the A2L checklist on the quote.

Residential use only — this is not a Manual J

This studio estimates a whole-house block load from state-level climate data and generic envelope assumptions. Final sizing requires a room-by-room ACCA Manual J load calculation, followed by Manual S equipment selection and Manual D duct design, performed by a licensed contractor.

Why Rule-of-Thumb HVAC Sizing Fails Modern Homes

Old "500 sq ft per ton" rules regularly oversize residential heat pumps by 40% to 75%. Oversized equipment short-cycles on humid summer afternoons, leaving indoor air clammy while increasing peak electrical demand. Use this preliminary estimator to sanity-check contractor quotes, and always request a written room-by-room ACCA Manual J load calculation before signing any replacement contract.