PC CEC-Listed · ResidentialUL 9540 (Ed. 2 : 2020)LFP (LiFePO4)

Power Center 5kW (14 kWh)

5.0 kW, 14 kWh, 240 Vac, energy storage system. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Usable Energy
14 kWh
Continuous Output
5 kW
Round-Trip Eff.
86%
1.5 kW Outage Runtime
8.7 hrs
Backup & Kit Actions
Compare vs Standby Generator →
Power Center 5kW — Illustrative category photo — not this exact model (residential battery & home backup system)
Illustrative category photo — not this exact model (residential battery & home backup system)The Solar House Project Editorial Archive
SINGLE-UNIT OUTAGE RUNTIME (14 kWh · 5 kW · LFP (LIFEPO4)) Light Load (0.8 kW) 13.5 hrsEssentials (1.5 kW) 7.2 hrsWhole-Home + HVAC (4.5 kW) 2.4 hrs

Storage Specifications & Safety Listing

Power Center 5kW Technical Specifications
ManufacturerPower Center
Model Number (MPN)5kW
Battery ChemistryLFP (LiFePO4)
Usable Energy Capacity14 kWh
Max Continuous Discharge5 kW
Round-Trip Efficiency (RTE)86%
PV DC Input (DC-Coupled)AC-Coupled / External Hybrid Inverter
Nominal AC Grid Voltage240 Vac
Safety ListingUL 9540 (Ed. 2 : 2020)
Certifying LaboratoryIntertek

Single-Unit Blackout Runtime Estimates

Modeled as usable kWh × √(RTE) ÷ load kW (14 kWh × 92.7% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.

Single-Unit Outage Runtime Estimates for 5kW
Light Essentials (0.8 kW — fridge, Wi-Fi, lights)16.2 hrs
Standard Backup (1.5 kW — + sump/freezer/home office)8.7 hrs
Heavy Load / HVAC (4.5 kW continuous)2.9 hrs

Multi-Unit Stacking Matrix

Multi-Unit Battery Stacking Runtime Matrix for 5kW
UnitsTotal kWhCont. kW1.5 kW Backup4.5 kW HVAC
1×14.0 kWh5.0 kW8.7 hrs2.9 hrs
2×28.0 kWh10.0 kW17.3 hrs5.8 hrs
3×42.0 kWh15.0 kW26.0 hrs8.7 hrs
4×56.0 kWh20.0 kW34.6 hrs11.5 hrs

Outage Sizing Notes & FAQ — Power Center 5kW

When sizing a residential storage bank around the Power Center 5kW (14 kWh usable, 5 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 8.7 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.

How long will one Power Center 5kW run during a power outage?
Using one-way discharge efficiency (√86% ≈ 92.7%) on 14 kWh usable capacity without solar recharge, one 5kW delivers approximately 16.2 hours at a 0.8 kW light-essentials load (fridge, Wi-Fi, LED lights) or 8.7 hours at a 1.5 kW standard backup load.
Can the Power Center 5kW run a central air conditioner or heat pump?
A single unit supplies 5 kW continuous AC power, enough to sustain a 4.5 kW HVAC load for roughly 2.9 hours on battery alone. Always verify Locked Rotor Amps (LRA) compressor startup surge and install a soft-start kit if your condenser LRA exceeds inverter peak surge rating.
Is the Power Center 5kW AC-coupled or DC-coupled, and what safety listing does it hold?
In the CEC registry (snapshot 2026-11-23), this LFP (LiFePO4) battery carries UL 9540 (Ed. 2 : 2020) certification (tested by Intertek) and is listed as AC-coupled / paired via an external hybrid inverter. Confirm UL 9540 / UL 9540A spacing rules with your local AHJ.

More Power Center Energy Storage Models

PowerCenter 5kW-AC100 (14.2 kWh)All Power Center Equipment →