Power Center PowerCenter 5kW-AC100 (14.2 kWh)
5 kW, 14 kWh, 240 Vac lithium battery storage system with the inverter component D-5kW100. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Storage Specifications & Safety Listing
| Manufacturer | Power Center |
|---|---|
| Model Number (MPN) | PowerCenter 5kW-AC100 |
| Battery Chemistry | LFP (LiFePO4) |
| Usable Energy Capacity | 14.2 kWh |
| Max Continuous Discharge | 5 kW |
| Round-Trip Efficiency (RTE) | 86% |
| PV DC Input (DC-Coupled) | AC-Coupled / External Hybrid Inverter |
| Nominal AC Grid Voltage | 240 Vac |
| Safety Listing | UL 9540 (Ed. 2 : 2020) |
| Certifying Laboratory | Intertek |
Single-Unit Blackout Runtime Estimates
Modeled as usable kWh × √(RTE) ÷ load kW (14.2 kWh × 92.7% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.
| Light Essentials (0.8 kW — fridge, Wi-Fi, lights) | 16.5 hrs |
|---|---|
| Standard Backup (1.5 kW — + sump/freezer/home office) | 8.8 hrs |
| Heavy Load / HVAC (4.5 kW continuous) | 2.9 hrs |
Multi-Unit Stacking Matrix
| Units | Total kWh | Cont. kW | 1.5 kW Backup | 4.5 kW HVAC |
|---|---|---|---|---|
| 1× | 14.2 kWh | 5.0 kW | 8.8 hrs | 2.9 hrs |
| 2× | 28.4 kWh | 10.0 kW | 17.6 hrs | 5.9 hrs |
| 3× | 42.6 kWh | 15.0 kW | 26.3 hrs | 8.8 hrs |
| 4× | 56.8 kWh | 20.0 kW | 35.1 hrs | 11.7 hrs |
Outage Sizing Notes & FAQ — Power Center PowerCenter 5kW-AC100
When sizing a residential storage bank around the Power Center PowerCenter 5kW-AC100 (14.2 kWh usable, 5 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 8.8 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.