ABB / FIMER official logoLegacy / Replacement ReferenceCommercial 3-Phase

ABB / FIMER PVS-175-TL-POWER-MODULE-2-US (179.574 kW)

175 kW, 800 V transformerless Grid Support Utility Interactive inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
179.574 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
850–1200V / 1200V
NEC 705.12 Breaker
175A @ 800V
Inverter Engineering Tools
Legacy / Replacement Reference: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
ABB / FIMER PVS-175-TL-POWER-MODULE-2-US — Illustrative category photo — not this exact model · Real commercial solar inverter installation
Illustrative category photo — not this exact model · Real commercial solar inverter installationWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 850–1200 Vdc 850V 1200V MAX 1200V PV DC INPUT ≤ 1200V DC 179.574 kW · 98.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 800V · 175A BRKR

Electrical & Grid-Support Datasheet

ABB / FIMER PVS-175-TL-POWER-MODULE-2-US Electrical and Grid-Support Specifications
ManufacturerABB / FIMER
Model Number (MPN)PVS-175-TL-POWER-MODULE-2-US
Inverter TopologyCommercial 3-Phase Inverter
Continuous AC Power (Paco)179.574 kW (179,574 W)
Nominal DC Input (Pdco)184,379 W
Nominal AC Voltage800 Vac (3-Phase)
CEC Weighted Efficiency98.5%
MPPT Operating Window850 – 1200 Vdc (NREL SAM Measured)
Max DC Input Voltage1200 Vdc
Max DC Input Current167.6 A
Night Tare Loss12 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for PVS-175-TL-POWER-MODULE-2-US
Max Continuous AC Current129.6 A @ 800V
125% Continuous Duty Current162.0 A
Minimum Standard Breaker175 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (197.53–242.42 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for PVS-175-TL-POWER-MODULE-2-US
Panel ClassRecommended QtyDC Array / Ratio
400W494–606 panels197.6–242.4 kW DC
440W449–551 panels197.6–242.4 kW DC
550W359–441 panels197.4–242.6 kW DC

CEC-Listed 240V Equivalents to ABB / FIMER PVS-175-TL-POWER-MODULE-2-US

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (179.574 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid

Isuna U20K-PH

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V19.378 kW
Base Power · Hybrid

000599.XX.Y

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V17.944 kW
SRNE Solar · Hybrid

HEBP48180U380-H

CEC Efficiency: 96.5%
Datasheet →

Engineering FAQ — ABB / FIMER PVS-175-TL-POWER-MODULE-2-US

What size circuit breaker does the ABB / FIMER PVS-175-TL-POWER-MODULE-2-US require under NEC 705.12?
At 179.574 kW continuous AC output on 800V (129.6A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the ABB / FIMER PVS-175-TL-POWER-MODULE-2-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 179.574 kW unit with 197.53 kW to 242.42 kW DC of solar modules without exceeding 1200V cold Voc.

More ABB / FIMER Inverters

PVS-166-TL-POWER-MODULE-1-US (165.954 kW)PVS-166-TL-POWER-MODULE-2-US (165.954 kW)PVS-175-TL-POWER-MODULE-1-US (179.574 kW)PVI-3.0-OUTD-S-US-A (3 kW)PVI-3.0-OUTD-S-US-Z-A (3 kW)PVI-3.0-OUTD-S-US-Z-M-A (3 kW)All ABB / FIMER Equipment →