BP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery HybridEstimated MPPT — Verify Manufacturer Datasheet

Base Power 000599.XX.Y (19.378 kW)

20 kW, 240 Vac Grid Support Utility Interactive Inverter, where XX are numbers and Y is a letter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
19.378 kW
CEC Weighted Eff.
96%
MPPT / Max DC
120–500V / 600VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
110A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Base Power 000599.XX.Y — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 19.378 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 110A BRKR

Electrical & Grid-Support Datasheet

Base Power 000599.XX.Y Electrical and Grid-Support Specifications
ManufacturerBase Power
Model Number (MPN)000599.XX.Y
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)19.378 kW (19,378 W)
Nominal DC Input (Pdco)20,185 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96%
MPPT Operating Window120 – 500 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design
Max DC Input Voltage600 Vdc
Max DC Input Current61.9 A
Night Tare Loss1344 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 000599.XX.Y
Max Continuous AC Current80.7 A @ 240V
125% Continuous Duty Current100.9 A
Minimum Standard Breaker110 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (21.32–26.16 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 000599.XX.Y
Panel ClassRecommended QtyDC Array / Ratio
400W53–65 panels21.2–26.0 kW DC
440W48–59 panels21.1–26.0 kW DC
550W39–48 panels21.4–26.4 kW DC

Compatible Solar Panels for Base Power 000599.XX.Y

Test any of 3,007 panels with this inverter →
Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (120–500 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
Compatible Solar Panels for Base Power 000599.XX.Y
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — Base Power 000599.XX.Y

What size circuit breaker does the Base Power 000599.XX.Y require under NEC 705.12?
At 19.378 kW continuous AC output on 240V (80.7A continuous), the 125% continuous duty rule requires a minimum 110A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Base Power 000599.XX.Y?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 19.378 kW unit with 21.32 kW to 26.16 kW DC of solar modules without exceeding 600V cold Voc.

More Base Power Inverters

MIN 9000TL-XH-US (9.063 kW)MIN 10000TL-XH-US (10.082 kW)MIN 11400TL-XH-US (11.52 kW)MIN 3000TL-XH-US (3.095 kW)MIN 3800TL-XH-US (3.888 kW)MIN 5000TL-XH-US (4.943 kW)All Base Power Equipment →