ABB / FIMER PVS-60-TL-US (60.033 kW)
60 kW, 480 V transformerless Grid Support Uitlity Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
60.033 kW
CEC Weighted Eff.
98%
MPPT / Max DC
570–800V / 800V
NEC 705.12 Breaker
100A @ 480V
Inverter Engineering Tools
Legacy / Replacement Reference: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | ABB / FIMER |
|---|---|
| Model Number (MPN) | PVS-60-TL-US |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 60.033 kW (60,033 W) |
| Nominal DC Input (Pdco) | 61,147 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 570 – 800 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 800 Vdc |
| Max DC Input Current | 84.9 A |
| Night Tare Loss | 0.9 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 72.2 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 90.3 A |
| Minimum Standard Breaker | 100 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (66.04–81.04 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 165–203 panels | 66.0–81.2 kW DC |
| 440W | 150–184 panels | 66.0–81.0 kW DC |
| 550W | 120–147 panels | 66.0–80.8 kW DC |
CEC-Listed 240V Equivalents to ABB / FIMER PVS-60-TL-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (60.033 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — ABB / FIMER PVS-60-TL-US
What size circuit breaker does the ABB / FIMER PVS-60-TL-US require under NEC 705.12?
At 60.033 kW continuous AC output on 480V (72.2A continuous), the 125% continuous duty rule requires a minimum 100A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the ABB / FIMER PVS-60-TL-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 60.033 kW unit with 66.04 kW to 81.04 kW DC of solar modules without exceeding 800V cold Voc.