Anker SOLIX official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Anker SOLIX A17E1 (7.687 kW)

7.68 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.687 kW
CEC Weighted Eff.
96%
MPPT / Max DC
350–450V / 450V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Anker SOLIX A17E1 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 350–450 Vdc 350V 450V MAX 450V PV DC INPUT ≤ 450V DC 7.687 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Anker SOLIX A17E1 Electrical and Grid-Support Specifications
ManufacturerAnker SOLIX
Model Number (MPN)A17E1
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.687 kW (7,687 W)
Nominal DC Input (Pdco)8,011 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96%
MPPT Operating Window350 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current20 A
Night Tare Loss8.23 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for A17E1
Max Continuous AC Current32 A @ 240V
125% Continuous Duty Current40.0 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.46–10.38 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for A17E1
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–24 panels8.4–10.6 kW DC
550W15–19 panels8.3–10.4 kW DC

Engineering FAQ — Anker SOLIX A17E1

What size circuit breaker does the Anker SOLIX A17E1 require under NEC 705.12?
At 7.687 kW continuous AC output on 240V (32A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Anker SOLIX A17E1?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.687 kW unit with 8.46 kW to 10.38 kW DC of solar modules without exceeding 450V cold Voc.

More Anker SOLIX Inverters

MI80 (0.896 kW)MI80H (1.068 kW)X1-P6K-US (6.04 kW)MI80S (0.656 kW)MI80L (0.78 kW)All Anker SOLIX Equipment →