Anker SOLIX MI80L (0.78 kW)
768 VA, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.78 kW
CEC Weighted Eff.
97%
MPPT / Max DC
36–43V / 43V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Anker SOLIX |
|---|---|
| Model Number (MPN) | MI80L |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.78 kW (780 W) |
| Nominal DC Input (Pdco) | 803 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 36 – 43 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 43 Vdc |
| Max DC Input Current | 20.6 A |
| Night Tare Loss | 0.03 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3.2 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 4.0 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.86–1.05 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.51× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.56× DC/AC) |
| 550W | 1 panel | 1:1 pairing (0.71× DC/AC) |
Engineering FAQ — Anker SOLIX MI80L
What size circuit breaker does the Anker SOLIX MI80L require under NEC 705.12?
At 0.78 kW continuous AC output on 240V (3.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Anker SOLIX MI80L?
As a 780W microinverter, it pairs 1:1 with panels rated roughly 819W to 1131W STC.