BP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Base Power MIN 11400TL-XH-US (11.52 kW)

11.4 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.52 kW
CEC Weighted Eff.
98%
MPPT / Max DC
250–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Base Power MIN 11400TL-XH-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–480 Vdc 250V 480V MAX 480V PV DC INPUT ≤ 480V DC 11.52 kW · 98% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Base Power MIN 11400TL-XH-US Electrical and Grid-Support Specifications
ManufacturerBase Power
Model Number (MPN)MIN 11400TL-XH-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.52 kW (11,520 W)
Nominal DC Input (Pdco)11,784 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency98%
MPPT Operating Window250 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current31 A
Night Tare Loss10 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for MIN 11400TL-XH-US
Max Continuous AC Current48 A @ 240V
125% Continuous Duty Current60.0 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.67–15.55 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for MIN 11400TL-XH-US
Panel ClassRecommended QtyDC Array / Ratio
400W32–39 panels12.8–15.6 kW DC
440W29–35 panels12.8–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Compatible Solar Panels for Base Power MIN 11400TL-XH-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Base Power MIN 11400TL-XH-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Base Power MIN 11400TL-XH-US

What size circuit breaker does the Base Power MIN 11400TL-XH-US require under NEC 705.12?
At 11.52 kW continuous AC output on 240V (48A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Base Power MIN 11400TL-XH-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.52 kW unit with 12.67 kW to 15.55 kW DC of solar modules without exceeding 480V cold Voc.

More Base Power Inverters

MIN 8200TL-XH-US (8.251 kW)MIN 9000TL-XH-US (9.063 kW)MIN 10000TL-XH-US (10.082 kW)000599.XX.Y (19.378 kW)MIN 3000TL-XH-US (3.095 kW)MIN 3800TL-XH-US (3.888 kW)All Base Power Equipment →