CP CEC-Listed · 240V ResidentialMicroinverter

Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4 (0.721 kW)

720 W, 240 Vac, Grid Support Utility Interactive Twin Microinverter (2 PV modules per inverter). Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.721 kW
CEC Weighted Eff.
96%
MPPT / Max DC
60–70V / 70V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 60–70 Vdc 60V 70V MAX 70V PV DC INPUT ≤ 70V DC 0.721 kW · 96% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4 Electrical and Grid-Support Specifications
ManufacturerChilicon Power (Generac)
Model Number (MPN)CP-720-60/72/96-208/240-MC4
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.721 kW (721 W)
Nominal DC Input (Pdco)756 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency96%
MPPT Operating Window60 – 70 Vdc (NREL SAM Measured)
Max DC Input Voltage70 Vdc
Max DC Input Current11.6 A
Night Tare Loss0.1 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for CP-720-60/72/96-208/240-MC4
Max Continuous AC Current3 A @ 240V
125% Continuous Duty Current3.8 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.79–0.97 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for CP-720-60/72/96-208/240-MC4
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.55× DC/AC)
440W1 panel1:1 pairing (0.61× DC/AC)
550W1 panel1:1 pairing (0.76× DC/AC)

Engineering FAQ — Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4

What size circuit breaker does the Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4 require under NEC 705.12?
At 0.721 kW continuous AC output on 240V (3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4?
As a 721W microinverter, it pairs 1:1 with panels rated roughly 757W to 1045W STC.

More Chilicon Power (Generac) Inverters

CP-250E-60/72-208/240-MC4 (0.289 kW)All Chilicon Power (Generac) Equipment →