Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4 (0.721 kW)
720 W, 240 Vac, Grid Support Utility Interactive Twin Microinverter (2 PV modules per inverter). Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.721 kW
CEC Weighted Eff.
96%
MPPT / Max DC
60–70V / 70V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Chilicon Power (Generac) |
|---|---|
| Model Number (MPN) | CP-720-60/72/96-208/240-MC4 |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.721 kW (721 W) |
| Nominal DC Input (Pdco) | 756 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 240V, 208V |
| CEC Weighted Efficiency | 96% |
| MPPT Operating Window | 60 – 70 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 70 Vdc |
| Max DC Input Current | 11.6 A |
| Night Tare Loss | 0.1 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 3.8 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.79–0.97 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.55× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.61× DC/AC) |
| 550W | 1 panel | 1:1 pairing (0.76× DC/AC) |
Engineering FAQ — Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4
What size circuit breaker does the Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4 require under NEC 705.12?
At 0.721 kW continuous AC output on 240V (3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Chilicon Power (Generac) CP-720-60/72/96-208/240-MC4?
As a 721W microinverter, it pairs 1:1 with panels rated roughly 757W to 1045W STC.