CP CEC-Listed · 240V ResidentialMicroinverter

Chilicon Power (Generac) CP-250E-60/72-208/240-MC4 (0.289 kW)

289 W, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.289 kW
CEC Weighted Eff.
96%
MPPT / Max DC
28–55V / 32V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Chilicon Power (Generac) CP-250E-60/72-208/240-MC4 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 28–55 Vdc 28V 55V MAX 32V PV DC INPUT ≤ 32V DC 0.289 kW · 96% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Chilicon Power (Generac) CP-250E-60/72-208/240-MC4 Electrical and Grid-Support Specifications
ManufacturerChilicon Power (Generac)
Model Number (MPN)CP-250E-60/72-208/240-MC4
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.289 kW (289 W)
Nominal DC Input (Pdco)303 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window28 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage32 Vdc
Max DC Input Current10.1 A
Night Tare Loss0.06 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for CP-250E-60/72-208/240-MC4
Max Continuous AC Current1.2 A @ 240V
125% Continuous Duty Current1.5 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.32–0.39 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for CP-250E-60/72-208/240-MC4
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.38× DC/AC)
440W1 panel1:1 pairing (1.52× DC/AC)
550W1 panel1:1 pairing (1.90× DC/AC)

Compatible Solar Panels for Chilicon Power (Generac) CP-250E-60/72-208/240-MC4

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Chilicon Power (Generac) CP-250E-60/72-208/240-MC4
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Mission Solar MSX10-460HN0B {C}460 W39.3 VDC/AC 1.59 (1 panel/input)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 VDC/AC 1.59 (1 panel/input)Verify Pair
SEG Solar SEG-460-BTD-HV460 W39.94 VDC/AC 1.59 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445445 W40.16 VDC/AC 1.54 (1 panel/input)Verify Pair
REC Solar REC440AA Pure-RX-DC440 W65.6 VDC/AC 1.52 (1 panel/input)Verify Pair
Canadian Solar CS6.2-48TM-460H460 W36.2 VDC/AC 1.59 (1 panel/input)Verify Pair

Engineering FAQ — Chilicon Power (Generac) CP-250E-60/72-208/240-MC4

What size circuit breaker does the Chilicon Power (Generac) CP-250E-60/72-208/240-MC4 require under NEC 705.12?
At 0.289 kW continuous AC output on 240V (1.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Chilicon Power (Generac) CP-250E-60/72-208/240-MC4?
As a 289W microinverter, it pairs 1:1 with panels rated roughly 303W to 419W STC.

More Chilicon Power (Generac) Inverters

CP-720-60/72/96-208/240-MC4 (0.721 kW)All Chilicon Power (Generac) Equipment →